2 -

PRELIMINARY INSTRUCTIONS

2-1 PACKAGING

The packing material of the power supply ALR3002M is intended to protect it during its transportation.
Keep it, it may be useful later one.
Packing list
1 instructions manual
2 cardboard packing piece
2-2 TECHNICAL FEATURES AT 230 V AND 23°C
2-2-1 AC voltages
Output voltage
Outputs
Output current
Protections
2-2-2 DC voltages
Output voltage
Outputs
Ripple
Regulation for a load change from 0 to 100% : 10mV
Regulation for a line change from -6% to +7% : 5 mV
Internal resistance
Visualization
Voltmeter resolution
Output current
Regulation for a load change from 0 to 100% : 2 mA
Regulation for a line change from -6% to +7% : 1 mA
Visualization
Ammeter resolution
OTHERS CHARACTERISTICS
Main input voltage
Input voltage
Consumption
Dimensions
Weight
Conditions of use
Conditions of storage
Conditions of moisture
Safety
EMC
Electric strenght
PROTECTIONS :
Safety class
Against short circuits
Against overtemperature
Against overcurrent

3- OVERALL VIEW

(see page 2)
3-1 CONTROLS DESCRIPTION
1 Main switch
2 AC outputs
3 DC voltage display
4 DC current display
1 plastic protecting bag
: 6V, 12V and 24 V ± 3% (+15% max without load ) with common point
: 4 mm diameter safety sockets
: 5 A
: Against short-circuits and overcurrent by incorporated thermal
circuit breaker (automatic rearmament after having deleted the
defect)
: 4 ranges 5 V, 6V, 12 V and 30 V adjustable from 0 V to V max.
: 4 mm diameter safety sockets
: 1 mV rms
: 4 mΩ
: Voltage regulation green LED
3 x 14 mm digits digital voltmeter
: 10 mV on 5 V and 6 V, 100 mV on 12 V and 30 V
: 3 ranges 25 mA, 250 mA and 2,5 A adjustable from 0 A to I max.
: Current regulation red LED
3 x 14 mm digits digital ammeter
: 100 μA on 25 mA, 1 mA on 250 mA, 10 mA on 2,5 A
: 230 V ± 10 %, 50/60 Hz
: Cord with 2 poles
: 200 VA
: L = 238 mm
H = 218 mm
: 4,2 Kg
: +5°C to +40°C
: -10°C to +50°C
: (see G.1)
: Class II reinforced safety between main input voltage and outputs.
EN 61010-1 standard - Overvoltage category II, pollution degree 2
: EN 61326-1
: 2300 V between input and output and between input and chassis.
: II
: by current regulation and thermal circuit breaker
: by controlled ventilation,
by power supplies shutdown,
by relay on the transformer,
by thermal circuit breaker incorporated on the transformer
: by internal 5x20 fuses (F1 : F5A 250 V , F2 : T3.15A 250 V)
1 power supply : ALR3002M
D = 90 mm
- 8 -
G.1
%
8 0
5 0
m a x i m u m
r e l a t i v e
m o i s t u r e
° C
3 1
4 0