TECHNICAL SPECIFICATIONS

MODEL
Nominal heat input: (Hs)
Appliance category:
Reference gas:
Normal gas pressure:
Injector size:
COUNTRY OF DESTINATION
I3+ for BE-CH-ES-FR-GB-GR-IE-IT-PT
I3B/P for CY-CZ-DK-EE-FI-LT-LV-MT-NL-NO-SE-SI-SK-BG-RO-TR
I3B/P for AT-DE
PROBLEM
Pilot will not light
Pilot will not stay on
Burner will not light
GUARANTEE AND SERVICE
Your new MaxxGarden product comes with a 12 month warranty. Defects affecting product func-
tionality may be corrected by replacement or repair provided the product is used and maintained
in accordance with the instructions. This does not apply to damage or wear sustained by improper
use of the accessories or the appliance. Your statutory rights are not affected. Documentation,
packaging, and product specifications may change without notice.
CUSTOMER SERVICES
If you wish to return your product for a full refund the item must be unused, in its original packaging
and returned in a sellable condition. Please contact our Customer Service team within 24 hours
who will be able to assist with your enquiry.
If they advise you to return the product to us please pack it carefully and include a note with your
name, address, daytime telephone number and details of the fault. If the product is still under
guarantee please include proof of purchase.
42
21967 FLAMEHEATER
10.5 KW
13+
13 B/P
G30/G31
G30
28-30/37mbar
30mbar
1.5mm
1.5mm
PROBABLE CAUSE
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connections
Debris around pilot
Loose connections
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Pressure is low
Opening blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Not in correct location
13 B/P
G30
50mbar
1.3mm
28-30/37mbar
30mbar
50mbar
SOLUTION
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Check all fittings
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill LPG tank.
Tank near empty. Refill LPG tank.
Remove and clean
Turn valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry