1. Continuous period work: press and hold the clock knob in the shutdown state to call
out the time setting, and 1~24 time periods will appear in sequence. It takes several
hours to work, that is, to set several time periods. For example: We need to set the
heater to work continuously for three hours at 7, 8, and 9 in the morning. Turn the clock
knob to the right to adjust to the number "7", click the clock knob key, a solid yellow line
appears below the number "7'", and then turn the knob to the right to adjust the
numbers "8" and "9". Wait for five seconds, and the setting is successful.
2. Working at Intervals: For example: We need to cancel the 8 o'clock among 7, 8, and 9
periods. Find the number "8", and click the clock knob. The small yellow line disappears,
wait for 5 seconds, the number "8" disappears, that is, the setting is successful. The
heater will start working at 7 am, and shut down at 8am and start again at 9am.
Timing Close
In the clock state, press and hold the clock knob key , the buzzer will sound once and the
screen will turn off. The timming close is completed.
Fault
Fault Description
Code
E0
Control unit error
E1
Failed to start (already
tried twice) / failed to
form a flame
Fault Analysis & Solutions
Replace the control circuit board.
① Fuel exhaustion: Please check whether there is
diesel in the fuel tank.
② There are bubbles in the oil line and the oil
supply is discontinuous.
③ Fuel pump is failed to pump diesel: Replace the
fuel pump.
④ Air inlet and exhaust are blocked: Check if
anything stuck the air inlet and exhaust outlet.