8 Changing the fuse
If the status LED (4) does not light up after you have inserted the adapter plug (3) into the
cigarette lighter socket in the vehicle, you should check the fuse installed in the adapter plug
(3) and replace it if necessary. Proceed as follows:
1. Turn the cap on the tip of the adapter plug (3) counter-clockwise.
2. Remove the defective fuse and replace it with a fuse of the same type (see "Technical
Data" section).
3. Reinstall the cap and turn it clockwise.
9 Cleaning and care
Important:
– Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions, as these may damage the housing or impair the functioning of the device.
1. Disconnect the product from the power supply and the connected devices before cleaning.
2. Use a dry, lint-free cloth to clean the product. Do not allow water to get inside the housing.
To prevent scratch marks, do not press too strongly on the surface when cleaning.
10 Disposal
All electrical and electronic equipment placed on the European market must be
labelled with this symbol. This symbol indicates that this device should be disposed
of separately from unsorted municipal waste at the end of its service life.
All owners of waste equipment are obliged to dispose of waste equipment separately
from unsorted municipal waste. Before handing the old device to a collection point,
end users are required to separate old batteries which are not enclosed by the old
device, as well as lamps which can be removed from the old device without any
damage.
Distributors of electrical and electronic equipment are legally required to accept waste
equipment free of charge. Conrad offers the following free return options (further information
is available on our website):
At our Conrad stores
At the collection points established by Conrad
At the collection points of public waste disposal agencies or at the collection systems set up
by manufacturers and distributors in accordance with the German Electrical and Electronic
Equipment Act.
The end user is responsible for deleting personal data on the old device before disposal.
Please note that in countries outside Germany, other obligations may apply to the return and
recycling of old devices.
11 Technical data
11.1 Power supply
Input voltage/current ..................... 12–24 V/DC, max. 12 A
Fuse .............................................. Fine-wire fuse, 15 A
Power consumption ...................... max. 100 W
Output voltage/current .................. 5 / 9 / 12 / 15 V/DC, 3 A; 20 V/DC, 5 A; max. 100 W
(USB-C
5 / 9 V/DC, 3 A; 12 V/DC, 2.5 A; max. 30 W
(USB-C
5 V/DC, 3 A; 9 V/DC, 2 A; 12 V/DC, 1.5 A
(USB-A port)
11.2 Ambient conditions
Operating conditions ..................... 0 to +40 ºC, 10–95% RH
Storage conditions: ....................... +10 to +55 ºC, 5–95 % RH
11.3 Other
Dimensions ................................... 90 x 60 x 20 mm (L x W x H)
Weight .......................................... 208 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in elec-
tronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE.
cable)
TM
connection)
TM
*2476162_v3_0622_02_DS_m_4L_(1)