English
Application
Free-standing communication ped-
estal made of sectional extruded
aluminium, powder coated /
painted, with base flange. Inclusive
of mounting frame to accommodate
functional modules.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
1 Scope of supply
KS/KSF 613/616-...
a Pedestal with floor flange
b Front panel
c 3x screw caps
d 3x hexagonal screws M 10 x 80
e 3x plain washers
f 3x heavy-duty dowels 16 x 60
LS 604/608-...
a Pedestal with floor flange
b Front panel
c 3x screw caps
d 3x hexagonal screws M 6 x 50
e 3x plain washers
f 3x threaded dowels 12 x 50
Mounting
Installation is only possible on
solid ground such as a concrete
foundation with "B 25" concrete
or pressure-resistant natural stone.
Foundation size 500 x 500 x 700
mm or ground slab of approx. 1 m²
and 150 mm thick.
For the light pedestal LS 604/608-...
a smaller foundation is sufficient.
For fixture in loose soil, ground spike
ZES/LS 611-... is available as an
accessory.
2 Remove the front panel
3 Mark the position of the fastening
holes and drill.
KS/KSF 613/616-...
16 mm dia. appr. 60 mm deep
LS 604/608-...
8 mm dia. appr. 60 mm deep
Insert the dowels, guide the con-
necting cable through the floor plate
and fasten the pedestal. Position the
screw cap.
4 Remove combination terminal
strip from the module packaging,
centre it turned around 45° to the
left on the retaining plate and latch
into position by rotating it around
a quarter turn in the clockwise
direction so that the terminal desig-
nations can be read vertically posi-
tioned one above the other.
5 Insert the front panel on the
column.
Inserting the modules
6 Connect the plug of the ribbon
cable to the combination terminal
strip. Applying a light pressure,
underpin the module in the module
slot of the MR 611-... opposite the
movable locking bolt. Exerting a
slightly higher degree of pressure,
clip into place on the other side.
Module removal
7 Remove the module from the
mounting frame: The unlocking
mechanism is actuated by pressing
in the Vario key, applying light pres-
sure. The opening for the Vario key
is located between two modules.
The Vario key is supplied together
with the mounting frame. Unlocking
releases one or two modules simul-
taneously. Access to the unlocking
mechanism can be additionally
secured using the pilfer safeguard
accessory ZDS 601-... and the pilfer
safeguard controller DSC 602-...
(see product information
ZDS 601-...).
Remove the front panel
8 The front panel can only be
removed if the directly adjacent
module has first been removed from
the mounting frame.
Servicing
9 Release the wire bracket on the
back of the module and lock into
position into the retainer on the
combination terminal strip. This
allows the modules to be function
tested and measured through. After
completion of servicing, suspend the
retaining bracket back onto the back
of the module.
Lettering
10 Open the call button module
using a screwdriver and remove the
inscription panel. To insert, underpin
the inscription panel on one side and
close by exerting a light pressure.
11 Remove the information module
by levering open the catch on one
side at the edge and removing
the inscription panel. To insert the
inscription panel again, underpin
on one side and close by exerting a
light pressure. The inscription inserts
made of special water-repellant
paper can be reordered as required.
Care instructions
To retain the optimum appearance
of the Siedle door loudspeaker, we
recommend regular cleaning using a
mild soap, followed by rubbing dry
with a soft cloth.