4.5.2
Sensor head heat alarm AHD
Parameter
Dimensions (ø W x H)
Heat detector type
Application area
Internal battery (permanently installed)
Service life
State indication
Low Battery
Normal operation
Alarm
Sound pressure of alarm
Ambient conditions
Ambient temperature operation
Ambient temperature storage
Maximum humidity
LED
Fire alarm
Increased sampling rate
Normal mode
Product description
Value
40 x 39 mm
Thermal
Private apartments/houses
Lithium battery 3 V, 1.6 Ah
Type CR123A, Li-metal
10 years with normal operation
(1 test per week)
A short acoustic signal sounds
and the red LED flashes every
48 seconds.
- When this acoustic signal
starts, the heat detector
AHD can be operated for
another 30 days or
4 minutes in the case of an
alarm.
The red LED flashes every
48 seconds.
Sound sequence
The red LED flashes every
0.5 seconds
85 dB
-10 ... 50 °C
-20 ... 60 °C
90 % (non-condensing)
Flashes every 0.5 seconds
Flashes every 2 seconds
Flashes every 48 seconds
Wireless heat detector AHD 10
EN