J. TECHNICAL DATA
Model
Type of stove
Capacity (*)
Electrical power consumption (ignition /
normal operation)
Electrical power supply
Recirculation airflow (min – max)
Thermal efficiency at nominal capacity /
reduced capacity (*)
CO level at 13% O
pacity (*)
Average dust content at 13% O
For rooms up to (**)
Exhaust gas outlet diameter
Flue gas temperature at nominal / redu-
ced capacity
Flue gas mass flow at nominal / reduced
capacity
Chimney draught needed
Chimney damper needed
Can be used on a combined flue / chim-
ney
Fuel (****)
Fuel dimension max length/diameter
Pellet hopper capacity
Autonomy (min-max)
Intermittend burning system
Primary air inlet
Recirculation fan
Recirculation air filter
Net weight
(*) According to EN 14785
(**) for indication only, varies per country/region
(***) needs to be determined by professional authorized installer
For your convenience you can download the latest version of the user-, installation-
and/or service manual on www.zibro.com/download.
1
4
112
nominal / reduced ca-
2
2
(****) Use only recommended fuel
Carmen
Wood pellets
W
3800-10400
W
370 / 150
V/Hz
230/~50
m
3
/h
140 – 230
%
81.8 / 72.1
%
0.015 / 0.034
mg/Nm
29
3
m
300
3
mm
80
°C
266 / 176
g/s
9.38 / 9.94
Pa
12
Possibly (***)
No
Pellets (Din+ / Ö-norm)
mm
30 / 6
kg
18
h
7 - 16
Yes
Yes
Yes
Yes
kg
100