After replacing the components, carry out a functional check.
Functional check: after cleaning, disinfecting or changing components check operation of the system. Inspect all essential components for
damage or dirt and, if required, replace these with original spare parts. If the red pennant of the airflow indicator shows insufficient air in
the air hood, although the pressure is correctly adjusted, this could indicate that a blockage has occurred in the filter system, the
compressed air hose, coupling or silencer. During this check, hold the air hood in the vertical (normal working) position.
Checking hose system for leakages: air supply hose and couplings, manual testing with pulling force. Connect the air hood to the
compressed air filter system and adjust the supply pressure; the filter system and air supply hose should not give audible leaks.
For COMMANDER VORTEX, as a result of intensive use and pollution of the compressed air system, it is possible that after some time,
the sound absorbers get blocked with oil or dirt. These can be replaced. See chapter Spare parts. To remove the filters, unscrew them
with a suitable screwdriver.

5. MAINTENANCE FREQUENCY

Clearance to start use:
Prior to use:
After use:
Every 6 months:
Usage duration of filters
Fluids will be drained continuously by the filter element. Pressure loss is caused by particles on the surface and in the microporous medium
of the filter element. It is advisable to renew the filters when a pressure difference of 0.6 bar occurs. For safety reasons, the activated-
carbon filter should be renewed at least every 6 months, or at the same time as the coarse filter.
6. STORAGE
After use and cleaning, store the entire system in a cool, dry and dark location. Take measures to prevent components of the system
coming into contact with oils, grease, solvents, acids or other chemicals.

7. SPARE PARTS

7.1
COMMANDER Shot blast helmet
No
1
2
3
4
5
6
7
8
9
9
10
10
11
12
13
14
For COMMANDER Series
15
16
17
18
19
For COMMANDER VORTEX
20
21
22
7.2
Compressed air filter set
No.
1
2
8. TECHNICAL SPECIFICATIONS
CLASSIFICATION
Nominal Protection factor (NPF):
Minimum operating pressure for Commander Series:
Minimum operating pressure for Commander VORTEX:
Minimum airflow with regulator at 5.5 bar working pressure and hose length 60 m:
COMMANDER series
Minimum airflow with VORTEX at 4.5 bar working pressure and hose length 60 m:
COMMANDER VORTEX
Maximum airflow with regulator at 7.5 bar working pressure and hose length 60 m:
Function and leakage inspection.
Performance check for the user, check of control valve.
Clean and disinfect the respirator: cleaning, functional check and leak test of the complete system.
Clean and disinfect the respirator: cleaning, functional check and leak test of the complete system.
Part no.
A160123
Wire mesh screen
A160761-25
Glass visor
A160722
Polyester visor
A160662
Visor gasket
A001979
Cantilever window
A160482
COMMANDER Airflow indicator
A160210
Headband
A160112-1
Neck seal
A000308
Cape, Bisonyl, black
A002495
Cape, leather
A002550
Jacket, cotton
A000233
Jacket, leather
A160695
Waist belt
A001976
Hose adapter on helmet
A161472
Sweatband
A165310
Cotton comfort hood
A002505
Hose assembly with bayonet and regulator
A160146
Silencer
A160676
Regulator
A160472
Regulator, silencer and CEJN nipple
A160549
Nipple CEJN, with ¼" inner thread
A161351
Hose assembly with bayonet
A160142
Sound absorber VORTEX SH (set)
A150275
VORTEX Air Conditioner
Part no.
Short description
A160042
AFU filter element
A160462
CEJN coupling, 1/2" for AFU (for second
connection)
Short description
EN-3
Packaging unit
50
25
50
1
1
1
1
5
1
1
1
1
1
1
1
5
1
1
1
1
1
1
Packaging unit
1
1
4B as per EN 14594
2000
5.5 bar
4.5 bar
175 L/min
145 L/min
385 L/min