Herunterladen Inhalt Inhalt Diese Seite drucken

Meccanica Fadini GASPO 254 Anleitung Seite 5

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

GASPO 254
- semiautomatic - with gas springs
400 V
R
S
T
N
400 V
NO
BOLLARD FITTING INTO THE HOUSING
To facilitate the fitting operations into the
enclosure, we advise to bring the bollard to
standing out position. Then sink the assembly
into the ground housing cylinder and fixing it by
the M10x20 TSEI SS steel screws.
6991
GB
Drwg. No.
GASPO 254 FUNCTIONING
Bollard springing up:
- make sure there is no voltage on Gaspo 254
- insert the spanner and turn anticlockwise
- the bollard rises on its own to 500 mm of height, then a "click" sound confirms it is securely
locked; with the bollard in fully standing position, two sockets (GEWISS GW 62 426) are made
available for use: a single-phase one (GEWISS GW 62 426) and a three-phase one (GEWISS GW
62 431)
- supply the installation with voltage
1
5x2,5 electric cable
inside the bollard
Bringing the bollard to down position:
and pre-wired to the
- disconnect Gaspo 254 from the electric power
sockets
- to lower the bollard into the housing cylinder turn the spanner anticlockwise; in this way
the retaining cog is unlocked
L = 2,5 m
- push the bollard down until it is flat with the ground level and a "click" sound confirms it is
locked in that position by the security cog
- keep the installation without voltage supply
1
2
400 V
NO
2
400 V
NO
INSTRUCTIONS GASPO 254
• 1 x three-phase electric power socket
• 1 x single-phase electric power socket
Three-phase socket
400 V
Single-phase socket
230 V
Insulation joint to extend the
inner electric cable on to the
outer cable. Make sure the gel
has come out and is spread all
around the electric cables.
3
"click"
3
"click"
4
400 V
4
400 V
NO

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis