FITTING OPERATIONS
Fix the anchoring plates to the ground housing cylinder by the provided bolts, then provide a suitable foundation plinth made of
reinforced concrete around it, according to the rule of the art and following the dimensions indicated in the drawing. The reinforced
metallic structure (not supplied by the manufacturer) is to be positioned around the ground housing cylinder very close to it in a
way that the anchoring plates be incorporated. The ground housing cylinder must be flat with the ground level.
Fixing plates
to cement
~ 70x70 cm
foundation plinth
0.0
SECTION VIEW OF THE PLINTH
Bollard finish
Complete Gaspo 254 weight
Weight of housing and plates
Impact resistance
[A]
Breakout resistance
[A]
[A] Various factors, such as the compaction index, soil permeability coefficient and kind
of concrete may reduce the values indicated even significantly.
6991
GB
Drwg. No.
M10x30 TEI screws
Ground housing cylinder
Gaspo 254
Metallic framework to be
provided as a reinforcement
to set in the concrete
foundation around the
ground housing cylinder
Gravel layer to provide
a soak-away system
Ground housing cylinder
Gaspo 254
Metallic framework to be
provided as a reinforcement
to set in the concrete
foundation around the ground
housing cylinder
Concrete foundation
Gravel layer
for water drainage
RAL 1028 melon yellow
68 kg
25 kg
30.000 J
160.000 J
INSTRUCTIONS GASPO 254
• 1 x three-phase electric power socket
• 1 x single-phase electric power socket
ø 10 n° 4 pcs.
600
OVERALL DIMENSIONS
ø 200
thickness 4 mm
120x206
ø 275