Herunterladen Inhalt Inhalt Diese Seite drucken

Error Message - ABSINA 52-230-1001 Bedienungsanleitung

Ev charging cable mode 2 | 3.7kw | max. 16a
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LED CHARGE STATUS INDICATOR
The status display is equipped with four indicator lights:
POWER
POWER:
CHARGE
CHARGE:
SIGNAL 1
SIGNAL 1:
SIGNAL 2:
SIGNAL 2

ERROR MESSAGE

The charging cable has several monitoring functions, which are indicated by the signal LEDs.
Description
Initialization
Connected
Charging
Charging completed
Failed self-test
Communication error
Over / low voltage
PE error
Over current
Leakage current
Charging overheated
=
= ON
OFF
Connected to power and ready for use
Charging process
Error message
Error message
Declaration
After mains contact, the control box carries out an initialisation with self-test.
Sleep mode.
Battery is charging.
Battery is full charged.
Internal fault in the control box. Send the charging cable to the manufacturer for
inspection.
The control box cannot establish communication with the EV. Check the connectors
for correct seating and for dirt in the de-energised state. If the fault cannot be
rectified, send the charging cable to the manufacturer for inspection.
The supply voltage is outside the tolerance range. Please check the mains voltage.
The control box detects a fault in the PE line. Please check your installation.
The charging current is above the maximum value. Stop charging and check the
compatibility of the charging cable.
The control box detects a fault current. Abort the charging process, disconnect the
charging cable from EV and check your wiring / vehicle. Visit a specialist workshop.
The control box is overheated. This can be caused, for example, by direct sunlight
during the charging process. The charging process is interrupted. After cooling
down, the charging process starts automatically.
= FLASH
Deutsch . English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis