Functioning by battery (only transmitter TX): max distance between TX and RX 6 m (one pair)
TX
RX
OFF
ON
=
All Dip-Switches in TX
and RX set to OFF
IMPORTANT: at each change of con gurations
!
of Orbita 57 it is necessary to turn o power
supply for 20 seconds onto the transmitter and
the receiver.
Functioning by 12 V / 24 Vac/dc: max distance between TX and RX 15 m (one pair)
TX
RX
OFF
ON
=
All Dip-Switches in TX
and RX set to ON
IMPORTANT: at each change of con gurations
!
of Orbita 57 it is necessary to turn o power
supply for 20 seconds onto the transmitter and
the receiver.
Synchronization up to 7 pairs 12 V / 24 Vac/dc supply voltage: max distance between TX and RX 15 m
IMPORTANT: at each change of con gurations of Orbita 57 it is necessary to turn o power supply for 20 seconds onto the transmitter and the receiver.
!
Installation where the receivers RX are all on one side and the transmitters TX are all on the opposite side.
1) From all the transmitters TX:
TX1
TX2
TX7
+
...
2) On all the Receivers RX:
RX1
RX2
RX7
+
...
3) Each pair TX and RX must have the same Dip-Switch con guration. (**) CENTERING PHASE: (instructions on page bottom).
MOST IMPORTANT: AMONG ALL THE POSSIBLE CONFIGURATIONS AVOID THAT WHERE ALL DIP-SWITCHES ARE SET TO OFF
AND CONFIGURATION 1 (ALL DIP-SWITCHES TO ON) MUST ALWAYS BE INCLUDED.
TX1
RX1
TX2
RX2
+
12 V / 24 Vac/dc 12 V / 24 Vac/dc
(**) CENTERING PHASE: for Orbita 57 in any mode of functioning
Important: power supply TX and RX. 4 minutes are available for this phase, during which the Blue Led is ashing and the Red Led is steady on thus indicating that
centering between Tx and Rx is no good. Drive the xing screw so that the cards are held in position, but not too hard, and adjust them until aligned: alignment is
achieved when the blue and red leds are both o , then tighten the xing screw thoroughly. The Red Led indicates centering failure (as well as obstacle detection),
while the Flashing Blue Led helps with centering by indicating that the infrared beam "cone" of the transmitter is only partly centered with the receiver.
After 4 minutes from powering, the Blue Led goes o , even if no centering has been achieved; it starts ashing again in case the batteries (if this option applies) are
running down. If the electrical power is disconnected, on powering back the photocells (should they not been aligned), the Blue Led ashes for 4 minutes (the time
available for a new centering), on expiring of this time, the led sets back to run down battery mode.
GB
6242
Drwg. No.
TX
Without Safety edge
Strip B
TX
1
=
2
3
In TX put strip B on
to PINS 1 and 2
With Safety edge
TX
TX
Without Safety edge
Strip B
TX
1
=
2
3
In TX put strip B on
to PINS 2 and 3
With Safety edge
TX
Remove the Strip C and
parallel connect the A and
B terminals of all the
transmitters in the system.
In case of installation on metallic structures, ground connect terminal A to better stabilize the system.
With all the required Tx transmitters,
position Strip B so to link the pins 2
and 3 to supply the units with
12 V / 24 Vac/dc electric power.
Series connect all the NC
contacts of the receivers
to the control board.
TX1
RX1 TX2
TX7
RX7
OFF
ON
1
...
=
2
3
All = ON
12 V / 24 Vac/dc
ORBITA 57
A B
RX
=
Strip C
A B
=
RX
NC Safety
edge
A B
=
RX
Strip C
A B
=
RX
NC Safety
edge
TX1
A B
+
Strip C
12 V / 24 Vac/dc
TX1
1
2
3
RX1
NO C NC
NO C NC
+
12 V / 24 Vac/dc
RX2 TX3
RX3 TX4
OFF ON
OFF ON
OFF ON
1
1
2
2
2
3
3
3
2 = ON
3 = ON
1 = ON
Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422
Fax +39 0442 331054
e-mail: info@fadini.net - www.fadini.net
TX
TX
n°2x1,5 V AAA
TX
TX
12 V / 24 Vac/dc
TX
TX2
A B
.....
Strip C
Strip C
12 V / 24 Vac/dc
B
A
TX2
Strip B
Strip B
1
+
2
3
RX2
RX7
NO C NC
.....
12 V / 24 Vac/dc
12 V / 24 Vac/dc
RX4 TX5
RX5 TX6
RX6 TX7
OFF ON
OFF ON
1
1
1
2
2
3
3
1 = ON
1 = ON
2 = ON
3 = ON
Directive 2012/19/UE
GB
Disposal of electric and
electronic material
DO NOT DISPOSE OF AS NORMAL WASTE.
HARMFUL FOR THE ENVIRONMENT
RX
(**)
CENTERING
PHASE:
12 V /
(instructions
24 Vac/dc
on page
bottom)
TX
RX
(**)
CENTERING
PHASE:
(instructions
on page
bottom)
TX7
A B
12 V / 24 Vac/dc
TX7
Strip B
1
2
.....
3
Control board
Elpro series
1
2
NC
RX7
OFF ON
1
2
3
2 = ON
3 = ON