Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
Photocells ORBITA 57: pair of infrared photocells, TX (transmitter) and RX (receiver), adjustable on the horizontal plane. Two options available:
1) The TX57 transmitter can be battery operated 2x1,5 V AAA or 12 V / 24 Vac/dc power supplied.
2) Synchronized operations achievable up to 7 pairs, but only with the 12 V / 24 Vac/dc power supply option: one on top of the other, all the TX's on to one side and all
the RX's on to the other. The barrier thus achieved is absolutely interference free (pair match Rx and Tx through the dip-switches).
For any required application use the NO and NC output contacts, and the NC input for the safety edge.
The manufacturer is not liable for other applications out of the scope here indicated.
Cover removal
Cover
Receiver RX
Strip A
NO
NC
12 V / 24 Vac/dc
NO and NC
output contacts
to be connected to
an Elpro control panel

TECHNICAL DATA

Power supply
Transmitter absorption
Receiver absorption
Protection standard
Working temperature
Distance range (*)
Max. rotation
Output contact
Battery life
Recommended cable section
(*) Distance decreases by approx. 30-50% in case of fog, rain or dusts.
a (m):
b
battery
b (cm):
a
12 V / 24 V
43 mm
6242
GB
Drwg. No.
Back bracket
Transmitter TX
OFF ON
Blue led
Red led
Strip C
A
B
12 V / 24 Vac/dc
n°2x1,5 V AAA
NC
- NC input contact for safety pro les
tted on to the edges requiring crash
prevention on closing.
- A and B inputs to be used when
synchronization between Tx and Rx
pairs is required.
2x1,5 AAA or 12 V / 24 Vac/dc
11 mA - 55 μA (by battery)
16 mA
IP 55
-20 °C +80 °C
6 m (by battery) - 15 m
200°
1 A - 125 V - 60 VA max
about 2 years
inferior to 0,5 mm²
4
5
6
7
8
9 10 11 12 13 14 15
15 10 10
80
70
50
98
42
ORBITA 57
Spigot
RX receiver
card
IMPORTANT: at each change of con gurations of Orbita 57 it is necessary
!
to turn o power supply for 20 seconds onto the transmitter and the
receiver.
Strip B
Strip A: by removing this strip, the connection to the control
Strip A
Strip B
Strip B: selects power supply mode either by cable or battery.
Strip C
Strip C: remove this strip when a safety edge is installed or
RX
- Blue Led: o = perfect centering
ashing = almost perfect centering ( rst 4 minutes of the installation)
ashing = batteries running down, to replace
- Red Led: on = no centering achieved, or photocells are obstracted
o = perfect centering
Manufacturer:
Address:
declare that the DoC is issued under our sole responsibility and
belongs to the following product:
is classi ed as type D device, according to the EN12453 standard,
paragraph 5.1.1.
is in conformity with the relevant Union harmonisation legislation:
- Electromagnetic Compatibility Directive 2014/30/UE
- Low Voltage Directive 2014/35/UE
40
30
Cerea, 15/03/2017
Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422
Fax +39 0442 331054
e-mail: info@fadini.net - www.fadini.net
Spigot xing
screw
200°
panels Elpro 62, Elpro 63, etc., provides indication of run
down batteries.
synchronization is required.
TX1
RX1
TX
12 V / 24 Vac/dc 12 V / 24 Vac/dc 12 V / 24 Vac/dc
UE DECLARATION OF CONFORMITY (DoC)
Meccanica Fadini snc
Via Mantova, 177/A - 37053 Cerea - VR - Italy
Photocell model ORBITA 57
Directive 2012/19/UE
GB
Disposal of electric and
electronic material
DO NOT DISPOSE OF AS NORMAL WASTE.
HARMFUL FOR THE ENVIRONMENT
_
+
+
_
TX2
RX2
TX7
RX7
+
...
Meccanica Fadini s.n.c.
Responsible Manager

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis