INSTALLATION AND CIRCUIT – FUEL
WATER/FUEL SEPARATOR FILTER
REF.
DESCRIPTION
1
Water/fuel separator filter
2
Fuel circuit shut-off valve
3
Replaceable filter cartridge
In order to protect the engine, a water / fuel separating filter is
NOTE:
placed on the engine's fuel supply circuit.
It is essential to replace the cartridge every 50 operating hours.
Contact the dealer network in order to purchase a replacement cartridge.
CAUTION
Changing the filter cartridge:
Follow ZODIAC's recommendations and those of the filter manufacturer. Follow the manual
or the engine manufacturer's instructions.
Place a draining funnel under the cartridge to be replaced.
Before replacing the filter, the pressure in the fuel feed system must be released.
INSTALLATION AND CIRCUIT – FUEL
1
2
3
500club 500
Page 30 / 59
540
580
660
Commenté [TI3]: Je suggère "fuel supply system" au lieu de
"fuel feed system" Je suggère 'must be relieved' au lieu de 'must be
released'.