Herunterladen Inhalt Inhalt Diese Seite drucken

JBM 60038 Bedienungsanleitung Seite 10

Elektrofettfüller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
TROUBLESHOOTING
Problem
Unable to pull back rod
Unable to push rod forward
No grease when trigger is pulled
Grease appears in relief valve
Motor does not run when trigger
is pulled
Grease leaks out of the back of the
grease tube
Possible cause
Vacuum build up
Pressure build-up
Rod is still connected to plunger
Grease tube is empty
Air pockets in the grease tube
Check valve is clogged
Zerk fitting is blocked
Battery
Rubber seal is flipped the wrong
direction
· 10 ·
Solution
Unscrew the purge valve to release vacuum.
Unscrew the purge valve to release pressure.
Rotate grease tube handle 90 degrees to
disengage it.
Add grease.
Refer to Purging Air Pockets.
Refer to Cleaning Contamination from the
Check Valve.
Disconnect coupler from fitting, clean zerk fitting
and grease path.
Make sure the battery is fully charged.
Refer to Preparing the Grease Gun for Suction
and Filler Pump Filling.
REF. 60038

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis