4

OPERATION

4.1

CHECK BATTERY CAPACITY

Press the battery capacity indicator (BCI) button. The
lights will illuminate according to the batteries capacity
level. See chart below:
1
Lights
Capacity
The battery is more than 78% ca-
4 Green Lights
pacity.
The battery is between 50% and
3 Green Lights
78% capacity.
The battery is between 35% and
2 Green Lights
50% capacity.
1 Solid Green
The battery is between 15% and
Light
35% capacity.
1 Blinking Green
The battery is between 10% and
Light
15% capacity.
The battery is under 10% capacity
Lights go out
and requires charging immediately.
1
Lights
Capacity
4 Green Lights
The battery pack is at full capacity.
The battery pack is at 70% capaci-
3 Green Lights
ty.
The battery pack is at 45% capaci-
2 Green Lights
ty.
The battery pack is at 10% capacity
1 Green Light
and requires charging soon.
The battery pack is under 10% ca-
Lights go out
pacity and requires charging imme-
diately.
1. BATTERY CAPACITY INDICATOR (BCI) BUT-
*
TON
2. LIGHT METRE
BATTERY PROTECTION FEATURES
This lithium-ion battery packs are designed with
features that protect the lithium-ion cells and maximize
battery life.
English
If the tool stops during use, release the trigger to reset
and resume operation. If the tool still does not work, the
battery needs to be recharged.
COLD WEATHER OPERATION
The lithium-ion battery pack can be used in
temperatures down to -14°C (6.8°F). Put the battery
pack on a tool and use the tool in a light duty
application. After about a minute, the pack will warm up
2
and begin operating normally.
5

TECHNICAL DATA

Model
Battery
Voltage per cell
Cell number
Charge time
Model
Battery
Voltage per cell
2
Cell number
3
Charge time
Model
Battery
Voltage per cell
Cell number
Charge time
Model
Battery
Voltage per cell
Cell number
5
G40B2 / 29717
36V
2.0AH, 72Wh, 40V MAX
3.6V
10
60 min. (use 2910907 / 29417 /
29447 Charger)
30 min. (use 2924107 Charger)
4 H (use 2904107 / 2904207
Charger)
G40B25 / 2925807
36V
2.5AH, 90Wh, 40V MAX
3.6V
10
75 min. (use 2910907 / 29417 /
29447 Charger)
37.5 min. (use 2924107 Charger)
4 H (use 2904107 / 2904207
Charger)
G40B4 / 29727
36V
4.0AH, 144Wh, 40V MAX
3.6V
20
120 min. (use 2910907 / 29417 /
29447 Charger)
60 min. (use 2924107 Charger)
8 H (use 2904107 / 2904207
Charger)
G40B5 / 2922607
36V
5.0AH, 180Wh, 40V MAX
3.6V
20
EN