Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Powertec Garden 2500W VS Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Maintenance
Do you have any technical questions? A claim? Do you
need spare parts or the Operating Instructions?
You will be helped quickly and without needless
bureaucracy at our webpage www.guede.com in the
Services part. Please help us be able to assist you. To be
able to identify your appliance when claimed, we need to
know its serial No., order No. and year of production. All
these details can be found on the type label. Enter the
details below for future reference.
Serial No.
Order No.
Year of production:
Tel.:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Servicing
Switch the appliance off before any servicing
and cleaning and wait until it fully stops.
Unplug the appliance.
Servicing works not explicitly specified in this manual must
be performed by specialised staff as there might be
dangerous situations the operator is unable to handle.
Spare parts may only be replaced by specialised staff.
Proceed as follows when the appliance is
blocked:
The suction/blowing tube may only be disassembled for
cleaning purposes. It must be properly refitted after
finishing the cleaning!
Cleaning
The appliance must not be cleaned by high-pressure
cleaners or under running water.
Do not use any aggressive, caustic cleaning agents.
After finishing your work, remove the collection bag
and turn it inside out. Clean the bag properly;
otherwise, mould and unpleasant smell could be
produced.
A severely dirty collection bag can be cleaned by
water and soap.
Keep the appliance and ventilation slots clean and
free at all times.
Any dirt on the appliance can be removed by a wet
cloth. Clean the suction tube with a wet cloth or
brush.

Troubleshooting

The table shows potential failures, their possible cause
and removal options. However, if you are unable to
remove the problem, contact a professional to assist you.
Switch off and unplug the appliance before any
servicing and cleaning.
Symptoms
Possible cause
No system voltage
Cable is defective
Appliance not
starting
Couplings on the
engine are not
tightened properly
Collection bag is
full
Appliance not
Suction tube is
sucking
blocked
Switch in "Blowing"
position
Appliance not
Switch in "Suction"
blowing
position
Remedy
Check the plugging
and protection
To be checked or
replaced in the
customer service
centre.
To be checked or
replaced in the
customer service
centre.
Empty the collection
bag
Clean the suction tube
Switch to "Suction"
Switch to "Blowing"