VII. Trouble Shooting
Below are the possible errors which can be displayed. The errors will only be
displayed when a button is pressed.
Error code
HOT
Over-heating protection
E02
Resist protection
E10
Motor abnormal protection
E20
Overload protection
E31
Undervoltage protection
E32
Overvoltage protection
E60
Out of step protection
If the error message persists after the reset procedure, please contact supplier
The initialization procedure must be completed before the first running after
table is installed or parts are replaced.
Description
Resolve
Hot: This protection may be initiated for continuous
long-term operation and should be re-powered or waited
for at least 18 minutes before use.
E02: During the movement, the table vibrates, is bumped
or the table is tilted, and immediately stops the move-
ment. The reverse movement is automatically released
after setting the distance, or press any key to stop and
release during the reverse running. It should be checked
and ensured that the table does not vibrate significantly,
hit obstacles or tilt and then run.
E10: Power should be removed, rechecked and ensure
that the motor and controller connections are reliable and
then powered back on.
E20: This alarm occurs when running up. Some heavy
objects on the table should be removed before running. If
this alarm occurs when running down, power off, remove
some heavy objects on the table, and then power on
again.
E31,E32: Power should be removed, rechecked and
ensure that the power supply to the controller is secure
and then powered back on.
Power should be removed, rechecked and ensure that
the motors in each channel are identical and their con-
nection to the controller is reliable and then powered
back on.
-17-