Herunterladen Diese Seite drucken

auer Ex-LED-Signal mDD1 Bedienungsanleitung Seite 4

Explosionsgeschützte leuchten

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Applic ation
Hazardous areas often require the use of optical signals for
warning, infor mation or signalling purposes. The Ex-LED
Light Expertline-LED provides these signalling options. The
available operating modes are C ontinuous light, S trobe light,
B linking light and R otating light, and turning on the supply
voltage activates the device. The Ex- Light is equipped with
high performance light-emitting diodes (LEDs) and comes
in the colours white, red, yellow, green and blue.
The housing conforms to protection
degree IP66 and is suitable for both indoor and outdoor use.
When looping through several devices successively, please
observe the maximum current consumption of 8 A.
Des ign
The plastic housing and the dome consist of impact-resi-
stant polycarbonate. The dome with the LEDs is completely
filled with transparent compound. The complete electronics
are also encapsulated in the compound. Thus, the "encap-
sulation" type of protection is established. The terminal room
has been designed according to the "increased safety" type
of pro tection.
The slide switch for adjusting the operating modes has the
'intrinsically safe' type of protection. A metal bracket serves
as wall mounting.
Mounting
The device may be placed in any position. The mounting
angle can be rotated 90°, requiring you to loosen the 4
hexagon socket screws using a 4 mm Allen key, rotating the
mounting angle in the desired position, inserting the screws
and tightening them. The device is fastened with 2 screws
(ø 6 mm or 8 mm) on the wall/ceiling.
S etting the operating modes
The operating modes are set using the four slide switches in
the terminal room.
The following operating modes may be set:
S trobe light
S witch 1 only to ON
B linking light
S witch 2 only to ON
R otating light
S witch 3 only to ON
C ontinuous light
S witch 4 only to ON
Obstruction light
No commutator to ON
(special construction, colour red)
If more than one switch is set to ON, then operating mode
„S trobe light" is activated.
Tec hnic al S pec ific ations
Optic al s pec ific ations
4
White
C olour location: x=0,33; y=0,33 according to C IE 1931,
Typical colour temperature: 5600 K;
R ed
Wavelength: 625 nm;
B rightness > 14 cd
in the operation mode „Obstruction light"
Yellow
Wavelength: 587 nm;
Green
Wavelength: 528 nm;
B lue
Wavelength: 470 nm;
C onnec ting the operating voltage
Open the terminal room on the underside of the Ex-LED
Light. Lay the connecting cable through the cable gland,
secure the connecting cable using the cable gland nut and
arrange the conductor ends (see drawing on page 10).
The Ex-LED Light Expertline LED comes in a direct current
24 V
version and in an alternating current 230 V
DC
In the case of the direct current version, please observe the
polarity of the connections. For the alternating current version,
the cable ends can be randomly connected. Then close the
terminal room with the terminal room lid.
Important note on c onnec ting the devic es
The cable glands must meet the requirements of protection
against
explosive
atmospheres,
-40°C
Ta
+70°C and IP degree of protection IP66. Use
only suited tools for connecting the cable and installing the
cable gland! The cable gland is suited for permanent wiring
only. E very time the terminal room has been opened, it
should be closed firmly and securely. The screw torque is
0.9 ... 1.1 Nm.
S ervic e
No maintenance required.
C ommis s ioning
After having been connected to the mains, the signalling light
is operational. S tart operating with closed housing only.
Operating utilization pos ition
Any
S tandard requirements
EN 60079-0:2006; EN 60079 – 18:2004, EN 60079-7:2007;
EN 600079-11:2007; EN 61242-0:2006; EN 61241-1:2004;
EN 61241-18:2004; EN 60529:2000
C are and maintenanc e
The signalling light contains no serviceable parts. The requi-
rements of EN 60079-17 regarding the regular control of the
explosion protection must be applied.
E M C - D i r e c t i v e
The device complies with the requirements of the new
EMC -directive 2004/108/EC and the low voltage directive
2006/95/EC .
The conformity with the above directives is confirmed by
the C E sign.
version.
AC
temperature
range

Werbung

loading

Diese Anleitung auch für:

Ex-led-signal mdd2