Operating instructions
DIGIMET AFM 30
5

Maintenance and care:

It is recommended that a filter be installed upstream. If the display is weak, disconnect the
battery in due time Protect the meter from excessive heat.
Check the pressure-carrying parts regularly for possible damage or wear. Replace defective
parts immediately with original parts.
If the system is not used for 2 weeks or longer, empty it completely and rinse it with a neutral
liquid (water).
Ordering spare parts:
When ordering spare parts, the following information is required:
Type specification, designation of the ET, order number
The following maintenance periods should be strictly observed to ensure trouble-free operation
DIGIMET AFM30
Check for loose connections
Readability and availability of
information
6
Notes in case of malfunctions:
Symptoms
No or weak LCD display
Quantity displayed is
inaccurate
Flow rate is reduced
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:00 49(0)6108-906-0 / Fax: 00 49(0)6108-906-120
Before each use
X
X
Possible causes
Weak battery
Battery contacts corroded
Incorrect calibration
Delivery rate too low
or too high
The pump system is dirty or has
crystallised urea
Turbine stuck
annually
According to
manufacturer
X
X
Removal
Replace both batteries
Clean the battery contacts
Perform a new calibration
Check and correct the system
delivery rate
Check the pump system and
rinse with neutral water
Clean the turbine
13