Changing the grinding time (user mode)
Single dose
To increase or decrease the single dose
The display (5) will show a blinking t1 and hundredths of
seconds (t1xx), which corresponds to the time set for the
single dose.
At this point, with the blinking indication t1x, change the
grinding time (and, consequently, the ground coffee dose) by
pressing the
and
keys. Five seconds after the last key is
pressed, the display will return to the doses counted and will
memorize the new time.
Note: the difference in grinding time for a single dose
user mode ranges between 0 and 50 hundredths of a second
(from 0 to 1/2 second).
Double dose
To increase or decrease the double dose
The display (5) will show a blinking t2 and hundredths of
seconds (t2xx), which corresponds to the time set for the
double dose.
At this point, with the blinking indication t2xx, change the
grinding time (and, consequently, the ground coffee dose) by
pressing the
and
keys. Five seconds after the last key is
pressed, the display will return to the doses counted and will
memorize the new time.
Note: the difference in grinding time for a double dose
the user mode ranges between 0 and 100 hundredths of a
second (from 0 to 1 second).
For correct application of the food safety system
(HACCP), please follow the instructions in this
paragraph.
General
To be performed at the end of the working day
The grinder-doser should be cleaned periodically, with special
attention given to those areas that come into contact with the
coffee.
To clean, follow these procedures:
Always switch off the appliance at switch (11) and cut off from
the mains via the omnipolar switch.
Do not immerse the appliance in water.
Cleaning the coffee beans receptacle (2)
Close the gate (3) pulling it towards the outside and separate
the coffee beans receptacle (2) from the grinder-doser.
Remove any remaining coffee from the coffee beans receptacle
(2).
Wash the receptacle with a damp cloth using methods and
detergents suitable to objects that come into contact with
foodstuffs. Rinse thoroughly and dry, removing any organic
residue.
Before replacing the coffee beans receptacle (2) on the grinder-
doser, ensure that all the parts have been dried thoroughly
press the
key.
in the
Manual operation
The grinder can also work in continuous or manual mode.
, press the
key.
For manual operation, simultaneous press and hold down
the single dose
(afterwards, release one key) or press and hold down one of
two keys for 2 seconds, and then press the second key without
releasing the first.
At this point, the grinder will start working. The display (5)
will start blinking and temporarily zero the doses counted up
until that moment, so it can count the doses distributed during
manual operation (partial counting).
in
After the continuous grinding mode is completed, the number
of doses for the partial count will be added to the total number
of doses.

7. Cleaning Operations

Bodywork
Clean the bodywork of the appliance with a soft cloth and
use products that DO NOT contain ammonia or abrasive
substances. Remove any organic residue.
N.B. Do not spray liquids inside the openings of the appliance.
19
5
and double dose
2
11
keys for 2 seconds