OPERATING INSTRUCTIONS
DDS-3025USB FUNCTION GENERATOR
ITEM NO.: 1188090

INTENDED USE

The function generator generates measurement signals in various wave forms and adjustable
amplitude.
Use the BNC sockets or digital connection to connect the product.
Observe the connection data contained in the included English user manual.
The whole product must not be modified or rebuilt and the housing must not be opened.
Any other than the intended use described above might result in product damage and
furthermore cause hazards such as short-circuiting, fire, electric shock, etc.
Do not operate the product in wet rooms or outdoors or under adverse ambient conditions.
Adverse ambient conditions are defined as such:
- wetness or excessive humidity,
- dust and flammable gases, vapors or solvents,
- thunder and lightning or similar conditions e.g. strong electrostatic fields, etc.
The safety instructions of these operating instructions must be followed without fail.
These brief instructions explain the safety precautions you should follow to make operating
the device as safe as possible. The included English user manual provides a detailed
description of the individual device functions.

SAFETY INSTRUCTIONS

Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in these operating instructions, we assume no liability
for any resulting personal injury or damage to property. Such cases will
invalidate the warranty/guarantee.
a) Persons / Product
• Unauthorized modifications and/or alterations to the product are not permitted due
to safety and approval reasons (CE).
• The device is not a toy. Keep it out of the reach of children and pets.
• Connect the measurement cable's BNC output to the generator before connecting
the measurement cable to the circuit you wish to meter. After measurement,
disconnect the measuring contacts from the circuit before disconnecting the BNC
output from the generator.
• Exercise extreme caution when handling alternating-current voltages >25 V (AC)
or direct-current voltages >35 V (DC)! Even at such voltages you can receive a
life-threatening electric shock upon contact with electric wires.
• Always check the device and connection cables for damage(s) before each
measurement. Never conduct measurements/functions if the protective insulation
is damaged (torn, missing, etc.).
• Do not use the device immediately prior to, during or just after a thunderstorm
(chance of lightning! / high-energy overvoltage!). Please make sure that your
hands, shoes, clothing, the floor, the measuring device, test leads, switches,
switching components, etc. are dry.
• Only use test leads/connection cables and accessories that meet the generator's
specifications for measuring/for device functions. Only use accessories with
double or reinforced insulation (e.g. fully insulated BNC adapter, etc.).
• If a safe operation cannot be assumed any longer, the device must be
decommissioned and be secured against accidental use. Safe operation is no
longer guaranteed when:
- the device is visibly damaged,
- the device no longer works and
- the device was stored for a long period of time under adverse conditions or
- the device has been subjected to considerable stress in transit.
All manuals and user guides at all-guides.com
VERSION 03/15
The device left the factory in a safe and perfectly working technical condition. To maintain
this condition and ensure safe operation, the user must observe all safety instructions and
warnings included in these instructions. Please observe the following symbols:
or

DELIVERY CONTENT

• Function generator
• USB cable
• BNC to BNC cable
• Software CD
• Operating instructions (these instructions)
• Operating instructions (English, on software CD)
• Never switch on the device immediately after it has been taken from a cold to a
warm room. The condensation generated could destroy the product. Leave the
device turned off until it has reached room temperature.
• Do not dismantle the product!
• Do not leave packaging materials lying around, they may become a dangerous
plaything in the hands of children.
• The product is only suitable for use in dry indoor spaces only (no bathrooms or
other wet rooms). Shield the device from becoming moist or wet. There is a risk of
fatal electric shock!
• For installations in industrial facilities, follow the accident prevention regulations
for electrical systems and equipment of the government safety organization or the
corresponding authority for your country.
• Handle the product with care; impacts, blows or falling from even low heights can
cause damage.
• Please observe the included detailed user manual.
b) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
A triangle containing an exclamation mark indicates important information in these
operating instructions that must be observed without fail.
The triangle containing a lightning symbol warns against danger of electric shock
or impairment of the electrical safety of the device.
The symbol alerts the user to the presence of important tips and notes on using the
device.
This device is CE compliant and fulfills all applicable European guidelines.
Only use indoors in dry locations.
Ground potential
GND
Ground potential chassis
Regularly check the technical safety of the device and test leads — i.e. for
damages to the housing or pinching, etc. Never operate the device with the
housing open.
Never exceed the maximum permissible input values. Do not touch any
circuitry or connection points when voltages exceeding 25 V/ACrms or
35 V/DC might be applied.
!RISK OF FATAL INJURY!