7 Installation
Important:
– Do not install the soap dispenser above a mirrored surface or close to running water as
this can unintentionally trigger the sensor.
– Make sure no bright light is aimed at or reflected towards the sensor.
– Do not install in areas where the product can get covered or splashed by water.
– Keep the product away from direct sunlight.
1. Remove the mounting plate (8) on the rear of the soap dispenser by lifting the tab and
sliding the mounting plate downwards.
2. Determine the correct mounting position using the mounting plate (8). Ensure a clearance
of at least 50 cm below the sensor.
WARNING
Risk of electric shock
Inadvertently puncturing electric cables can cause life-threatening electric shock!
Before wall mounting, ensure that there are no cables or pipes located underneath the
surface.
3. Secure the mounting plate (8) to the wall using the supplied screws and rawlplugs.
8 Operation

8.1 Installing batteries

1. Remove the battery compartment (7) cover on the base of the product.
2. If necessary, remove the old batteries.
3. Insert four AA batteries. Ensure the correct polarity. The positive and negative terminals are
marked on the batteries and on the inside of the battery compartment.
4. Replace the battery compartment cover (7).
Note:
– If the LED display (4) flashes continuously, the batteries need to be replaced.
8.2 Filling with disinfectant
Important:
– Please note that the soap dispenser is only suitable for disinfectants.
1. Unlock the container closure (1) with the key provided.
2. Open the cover (2).
3. Pour disinfectant into the product container (3).
4. Close the cover (2).
5. Lock the container closure (1) with the key provided.
9 Operation

9.1 Selecting the operating mode

Press THE ON/OFF switch (6) to select the different operating modes:
Press once:

Switch on soap dispenser, output 0.8 ml of disinfectant each time the sensor is triggered
2x press:

Output 1.2 ml of disinfectant each time the sensor is triggered
Press three times:

Switch off soap dispenser
9.2 Dispensing disinfectant
1. Switch on the soap dispenser by pressing the ON/OFF switch (6) (see „9.1 Selecting the
operating mode").
2. Place your hands under the sensor at the bottom of the soap dispenser. The range of the
sensor is approx. 5 - 8 cm.
3. Wait a few moments for the disinfectant to dispense.
10 Troubleshooting
Fault
Reason
The
sensor
does
not
The soap dispenser is
respond.
switched off.
Batteries are drained.
There is a light source
under the sensor or there
are reflections.
Fault
The sensor responds, but
no disinfectant is emitted.
The soap dispenser emits
too much or too little
disinfectant.
11 Cleaning and care



12 Disposal
12.1 Product
12.2 (Rechargeable) batteries
If a battery is inserted, remove it and dispose of it separately from the product. You as the end
user are required by law (Battery Ordinance) to return all used batteries/rechargeable batteries.
Disposing of them in the household waste is prohibited.
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold. You thus fulfill your statutory obligations
and contribute to the protection of the environment.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit
and their exposed terminals should be covered completely with insulating tape before disposal.
Even empty batteries/rechargeable batteries can contain residual energy that may cause them
to swell, burst, catch fire or explode in the event of a short circuit.

13 Technical data

Power supply ................................ 6 V, 4x 1.5 V AA batteries
Battery service life ........................ Approx. 2200 output processes or 4 - 6 months
Suitable products .......................... Disinfectant
Container volume ......................... 700 ml
Sensor range ................................ approx. 5 - 8 cm
Sensor response time ................... 0.25 sec.
Product material ........................... ABS, PS
Working temperature .................... +10 to +40 °C
Operating humidity ....................... 0 – 85 % RH
Storage Temperature .................... +5 to +40 °C
Storage humidity ........................... 0 - 85 % rH
Dimension (WxHxD) ..................... 111 x 180 x 100 mm
Weight .......................................... 450 g
Solution
Switch on the soap
dispenser.
Replace the batteries.
Ensure the correct position
of the soap dispenser.
Reason
There is no disinfectant in
the container.
There is air in the system.
The disinfectant is too thick.
An incorrect operating mode
has been selected.
Important:
– Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions, as these may damage the housing or impair the functioning of the device.
– Do not immerse the product in water.
Switch off the soap dispenser before cleaning.
Wipe the product with a dry, fibre-free cloth.
To prevent scratch marks, do not press too strongly on the surface when cleaning.
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
Batteries/rechargeable batteries containing hazardous substances are labelled
with this symbol to indicate that disposal in household waste is forbidden. The
abbreviations for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb
= Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in
electronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is
prohibited. This publication reflects the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE.
Solution
Refill with disinfectant.
Trigger the sensor several
times.
Use a disinfectant.
Change the operating
mode.
*2481642_v2_1221_02_DS_m_4L_(1)