UK
1
When the heat pump
starts
When the heat pump is
running
2
When the heat pump
starts
When the heat pump is
running
Parameter
Tset
Tset-1
Tset+1
The graph on the right illustrates how the heat
pump set to 28°C with Auto mode regulates the
water temperature.
6.5 How the Heating Mode works
Working
NO
status
MV-1420-1421-04-2022 . eeese-aircare.com . © All rights reserved eeese air care ApS
Startup
Heating mode
Standby
Cooling mode
Standby
Startup
Heating mode
Standby
Cooling mode
Standby
Explanation
T water temperature setting.
For example : Tset = 28°C water temperature setting
Minus 1°C than Tset temperature.
For example: 28-1=27°C
Plus 1°C than Tset temperature.
For example: 28+1=29°C
T1=Water inlet temperature /Tset= set temperature=28°C
Water inlet
Working mode
Temperature
T1≤27°C
T1≥29°C last for 3 minutes
T1≥30°C
T1=28°C, last for 3 minutes Standby
T1≤27°C, last for 3 minutes It switches to heating mode
27°C<T1≤29°C
T1≥29°C, last for 3 minutes Standby
T1≥30°C
T1=28°C, last for 3 minutes Standby
T1≤27°C, last for 3 minutes It switches to heating mode
Example
Heat pump working level
Heating mode
Standby
It switches to cooling mode
Heating mode
It switches to cooling mode
133