Herunterladen Inhalt Inhalt Diese Seite drucken

Jula 071029 Gebrauchsanleitung Seite 35

Winkelschleifer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
2.
Apply a few drops of pneumatic oil in the
tool's air intake. Do not use oil with a high
viscosity. This can impair tool performance.
3.
Connect the tool to the compressed air supply. Operate the tool with no load for a few seconds to
distribute the oil. Any surplus oil may be thrown out from the chuck. Aim the tool in a safe direction.
4.
Before putting the tool away after use, disconnect the air hose and apply 4 or 5 drops of pneumatic
oil in the air intake. Reconnect the air hose and operate the tool for approx. 30 seconds to
distribute the oil evenly. This will ensure the tool lasts longer.
5.
Do not store in a damp location. This can result in corrosion damage to the mechanism. Always
lubricate the tool before storage.
6.
When a product has come to the end of its useful life it must be recycled in compliance with
regulations in force. The tool must not be incinerated.
Problem
Possible cause
The tool operates
1.
slowly or not at
all.
2.
3.
4.
5.
6.
7.
Abnormal
Inadequate lubrication.
vibrations and/or
heat in the tool.
NOTE! Contact your dealer if you detect a problem that is not included in this troubleshooting guide.
TROUBLESHOOTING
Action
The tool is
1.
clogged.
2.
No oil in the tool.
Low air pressure.
3.
Air hose leaking.
Pressure drop.
Worn rotor
4.
blades.
Water is
5.
emerging through
the tool's air
outlet.
6.
7.
Follow the lubrication instructions.
ENGLISH
Clean the tool with pneumatic oil or solvent.
Lubricate the tool according to the lubrication
instructions.
a. Set the regulator on the tool to max.
b. Set the regulator on the compressor to the maximum
permitted operating pressure for the tool (6.2 bar).
Tighten and seal any leaking connections. Use sealing
tape.
a. Use a hose with the correct dimensions. A long hose
or a tool that has a high air consumption may require a
hose with an inner diameter of 1/2" or larger,
depending on the total hose length.
b. Do not use several hoses linked together with quick-
release couplings. This will cause a pressure drop and
cause the tool to work less efficiently. Connect the
hoses directly.
Replace the rotor blades.
Drain out the water from the air container (see the
compressor manual). Lubricate the tool and operate
until no water can be seen. Lubricate the tool again
and operate for 1–2 seconds.
35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis