CAUTION:
Avoid a pressure of 35 psi or more! Check the pressure gauge. If the displayed value decreases, the
leakage is in the cooling system.
The cooling system has a leak, if there is pressure drop or water loss,.
2.
Radiator Cap Leakage Test
Remove the original radiator cap.
Choose the appropriate joint 2a or 2b and connect it to the radiator cap.
Press the test pump for few times and watch the pressure gauge. The pressure falling if the cap
is defective. (see fig.3)
Compare the measured pressure values with the standard-pressure of radiator cap..
M A I N T E N A N C E / S T O R AG E
Attach the Test Adapter to quick coupler of Hand Pressure Pump, then press the Hand Pressure
Pump few times to push remnant water out the Test Adapter.
Drop pneumatic oil into the air hole of the Hand Pump end to lubricate the piston of Hand Pump.
NOTE
These instructions do not replace the service literature. You may find additional information in
serviceliterature. For all tests vehicle-specific data should be present, without this data can adequate
results are not ensured.
2 1 0 0 0 L
7

Werbung