Herunterladen Inhalt Inhalt Diese Seite drucken

Electronic Functions - clage EKE Gebrauchs- Und Montageanleitung

Sensorarmatur
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electronic functions


signs and symbols
XXX

function
Remove lable
1x
fi rst startup
after installation
wait
wait till
temporary off
«cleaning mode»
2x
activate
1x
temporary off
stop
or automatic
1x
continous run
1x
activate
1x
continous run
stop
or automatic
follow up
1x
time control
1x
for normal operation
keep touched
set / programm
after releasing
time of waterfl ow
1x
for continous on
and
purge duration for
1x
line purge feature
set / programm
after releasing
line purge feature
activate / deactivate
1x
«automatic fl ush on
set intervall»
wait till
2x
restart electronics
1x
release and wait till
wait till
2x
sensor range
1x
set / programm
release and wait till
wait till
security off
empty battery
6
- press Click-plus
1x
- water fl ows
- waterfl ow stops
h
- hours / min. - minutes / sec. - seconds
feedback
procedure
signal

min. 3 sec. till
+
1x
a app. 0,5 sec.
app. 2 sec.
1x
1x
app. 2 sec. till
1x
minimum 3 sec.

(max. 5 sec.)
XXX

app. 2 sec.
XXX

app. 5 sec. till
1x
0 - 10 sec.
+
1x
minimum 3 sec.

(max. 5 sec.)
keep touched till
1x - 40x
+
app. 25 sec. till
1x - 4x
1x
a app. 0,5 sec.
app. 5 sec. till
4x
+
1x
a app. 0,5 sec.
app. 15 sec. till
1x - 8x
+
1x
XXX

permanent
- hand/object within sensor area
- LED fl ashes GREEN
- LED fl ashes RED
information
remove hand/object from sensor area

2x/sec., keep out of sensor area
confi rmation, ready for operation
pulsing during active function
manual stop
automatic after preset time
extended function mode is active
water fl ows after releasing
manual stop
automatic after preset time
1x/sec., water fl ows during touching -

releasing defi nes duration
confi rmation, ready for operation
touch max. 5 sec., water fl ows after releasing,
+
number of
(1x-40x) shows current setting
1x
=0,5 min. .... 40x
releasing defi nes duration
check / confi rmation of setting by repeating
1x
number of
(1x - 40x) according to setting
1x= off,
2x=12h,
ignore fl ashes after 5 sec. and 10 sec. - keep
touched till
1x - 4x aftter app. 25 sec.,
releasing defi nes interval
confi rmation, ready for operation
pulsing during active function
1x/sec.

1x/sec., keep out of sensor area
confi rmation, ready for operation
pulsing
1x = min. ......
8x = max.
ignore fl ashes
4x after 5 sec., keep touched
till
1x - 8x after app. 15 sec., releasing
defi nes sensor range step

1x/sec., keep out of sensor area
confi rmation, ready for operation
when
without movement only
2x/sec. during dedecting hand / object
default
-.
2 min.
2 min.
1 sec.
2 min.
= 20,0 min.
3x= 24h
off
-
6
-
-
setting
range via
Click-plus
-
-
0,5-20 min.
(in 0,5 min.
steps)
0-10
sec.
0,5-20
min.
(in 0,5 min.
steps)
off
12 h
24 h
-
1-8 steps
-
-
74.074.CL15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis