HANDLE
CARTRIDGE
COVER
RETAINING
NUT
CARTRIDGE
47003001
Before use: Unscrew the Aerator and allow the water to run freely for 5 minutes. Then screw the fi lter
back in place.
Periodically: Unscrew the Aerator and remove. Rinse it with running water until any loose debris is
cleared. Then replace the Aerator and tighten.
To Change the Cartridge
CAP
ALLEN
KEY
GRUB
SCREW
Cleaning
Operation
on
off
First shut off the water supply to the tap.
1. Pull out the cap from the handle.
2. Loosen the grub screw in handle, but do not
remove it.
3. Take off the handle, unscrew the cartridge
cover.
4. Using a correct size spanner unscrew the
retaining nut.
5. Pull the cartridge and wash it with clean running
water.
6. Dry and lightly grease the seals (only use
silicone grease)
7. Replace them in turn.
hot
cold