3. Prior to use

Ensure that the compressor is switched on and that it has been set to the correct operat-
ing pressure. Check that the compressor is regularly inspected and maintained.
A worn and/or dirty compressor supplies polluted air that will not be cleaned by the filter
system! Make sure that the compressor cannot suck in any dangerous matter via the air
inlet.
Adjust the operating pressure on the BAF airline filter to a minimum of 4.5 bar. Connect
the Contracor CCT Air Conditioner via the brathing air supply hose to the BAF airline filter
system.
Make sure that the Contracor CCT Air Conditioner is correctly secured to the belt, that the
helmet connection of the hose for the breathing air is not leaking, and that the hose is
sufficiently secured against inadvertent release. Refer to paragraph "Maintenance and
inspection". Continue with a test run of at least 3 minutes when using the equipment for
the first time.

4. During use

During use
Adjust the air volume according to requirements.
Contracor COMFORT
The desired temperature of the breathing air is reached within a short time.
The air flow indicator in the blast helmet will warn the user if insufficient air is supplied.
Immediately leave the working area if there is an interruption in the air supply.
Ensure that the breathing air supply hose cannot be trapped, causing interference with
the air supply or preventing a rapid departure from the work area. The Contracor CCT Air
Conditioner does not reduce the environmental noises. The use of supplementary audio
protection is mandatory. It is quite normal that a certain amount of air escapes from the
unused air outlet. Comply with the instructions relevant to the chosen blast helmet.