Excessive air humidity, or excessive supply pressure, can cause the sound absorber on the
cold side to freeze. The air flow from the cold side will then reduce suddenly. Switch off the
Contracor CCT Air Conditioner. After a few minutes, the Contracor CCT Air Conditioner will
have thawed out, allowing the work to recommence. Reduce the supply pressure or change
the position of the regulator valve; so avoiding recurrence of the freezing. A defective
compressed air de-humidifier or an air de-humidifier with insufficient capacity could also be
the source of such problems.

10. Technical specifications

Usage of the Contracor CCT Air Conditioner does not interfere with the protection
factor NPF.
Operating pressure: ................................................................................ 4.5 bar dynamic
Min. supply at 4.5 bar operating pressure, with 40 m hose: ............................. 165 l/min
Min. compressed air usage at 5 bar operating pressure, with 40 m hose: ....... 350 l/min
Minimum ambient temperature: .............................................................................. -10 °C
Maximum ambient temperature: ............................................................................ +60 °C
Maximum hose length: ............................................................................................... 40 m
Maximum operating pressure: ................................................................................... 7 bar
Noise level at 5.5 bar and maximum air flow: ...................................................... 90 dB(A)
Weight on the belt: .................................................................................................... 400 g

11. Performance data

pressure
warm
max.flow
4,5
180
5
210
5,5
540
Pressure:
The dynamical pressure, measured in bar (operating pressure)
Flow:
The amount of transported air in litres per minuute (l/min)
Temp.:
The tempirature diference betweenthe incoming and outgoing air in degress Celsius
and measured after 3 minutes of operation.
The Compressed air usage is measured in niminal litres mer minute (Nl/min)

12. Spare parts

The following spare parts are separately available:
Article No.
Code
30306
30307
CONTRACOR
CCT Art. 30305
®
cold
temp.
min.flow
+18
230
+18
260
+17
290
Description
Sound absorber G¼" (2 pcs. set)
Screw connection nipple for Comfort helmet installation
compressed ar usage
temp.
-16
400
-16
430
-15
490
11