3E-490044NI – 03/20
FREQUENCY OF MAINTENANCE AND LEVEL OF USE PER DAY
- Go into the service screen
- Press the "installation parameter" button
- Enter the PIN code for the installer "INSB"
- Validate "V": when all the code has been entered and it is correct access the menu or start on the PIN number again.
- Enter the number of hours before the next service visit (1500 hours by default): « HSr ». Adjustable from 100 to 5000 hours. Allow at least one
service per year.
* Select the value to be modified
* Adjust the value using the coder
- Enter the average hours per day that the unit is likely to operate: « H-d ». Adjustable from 1 to 24 hours.
* Select the value to be modified
* Adjust the value using the coder
WATER TREATMENT CAPACITY
This only functions if there are 2 separate supplies to the oven.
- Go into the service screen
- Select "Client parameters"
- Enter the PIN code "CHEF" Permanent password (upper or lowercase)
- Validate "V": when all the code has been entered and it is correct access the menu or start on the PIN number again.
- Modify or check the water treatment capacity (in litres). Set to zero by default (if there is not a dedicated water treatment system for the oven).
* Select the value to be modified
* Adjust the setting using the coder
- Reset the counter if required.
* Press « RESET »
* Confirm by pressing « YES »
Page 1

PARAMETER ADJUSTMENT

Frequency of maintenance
Level of use per day
The water treatment system capacity in litres. Reset. Set
to zero by default (if there is no dedicated water treatment
system for the oven)