Starting and stopping the pump when supplied by an auxiliary pump

C
UN003597-IT
To start the pump, proceed as described below.
1) Open the shut-off valve (M).
2) Open the by-pass valve (G) to depressurise the deliv-
ery pipeline.
3) Start the auxiliary pump (C).
4) Start the pump (D) and run it for a few minutes with
no pressure.
5) Adjust the by-pass valve (G) to obtain the pump's op-
erating pressure.
English language
INSTRUCTIONS FOR USE
D
To stop the pump, proceed as described below.
1) Open the by-pass valve (G) to discharge the pressure.
2) Stop the pump (D).
3) Stop the auxiliary pump (C).
4) Close the shut-off valve (M).
35
F
G
Use and Installation