Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (= open water
heaters) is not possible.
Technical data
• Flow pressure
- min.
- recommended by 29 043, 29 044
- recommended by 29 064
diverter automatically
diverter seccured manually
• Operating pressure max.
• Test pressure
A pressure reducing valve must be fitted in the supply line if
static pressures exceed 5 bar to satisfy noise level ratings.
Avoid major pressure differences between hot and cold water
supply.
• Temperature
Hot water inlet:
Recommended (energy saving):
• Water connection
Note:
This fitting can be combined with head and hand shower sets
by using a 3-way diverter.
Important note:
Never install shut-off valves in the outlet pipe (mixed
water) downstream of any built-in mixer.
Installation
Prepare the wall for the installation.
• Prepare the holes for the single lever mixer and slots for the
pipes.
Align single lever mixer using fitting template and fit,
see fold-out page I, Figs. [1] and [2].
• Permissible tolerances are given on the dimensional
drawing.
• The arrow on the fitting template must point upwards.
• To align place a spirit level on the fitting template, see
Fig. [1].
• The housing is provided with pre-drilled holes (B) to facilitate
mounting the fitting to the wall.
• The finished surface of the wall (C) must lie within the
area (X) of the fitting template, see Fig. [2].
• The cold water supply must be connected on the right, hot
water supply on the left.
Connect pipes.
Open cold and hot-water supply and check connections
for water-tightness.
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Plaster and tile the wall, see Fig. [3].
Attention! You must tile directly to the fitting template!
Do not remove the fitting template before final installation.
Final installation
Remove fitting template, see Fig. [4].
Install escutcheon and lever, see Figs. [5].
Seal the escutcheon with silicone.
Check mixer for correct operation, see Fig. [6].
0.5 bar
1 - 5 bar
Function of automatic diverter (D) for 29 043, see Fig. [6].
1 - 5 bar
Pulling the lever will release water delivery.
0.7 - 5 bar
On the bath mixer, water will always emerge from the lower
outlet first (e.g. bath outlet).
< 0.7 bar
Pressing diverter (D) shuts off the flow of water to the bath and
10 bar
delivers water to the shower outlet.
16 bar
When the mixer is closed, the diverter is released
automatically so that when the mixer is opened again, water
will always emerge from the lower outlet first (e.g. bath outlet).
Function of manual diverter (E) for 29 064, see Fig. [7].
max. 80 °C
Pulling the lever will release water delivery.
60 °C
On the bath mixer, water will always emerge from the lower
hot - left
outlet first (e.g. bath outlet).
cold - right
Pressing diverter (E) shuts off the flow of water to the bath and
delivers water to the shower outlet.
In addition, the diverter assembly can be secured manually
(advantageous at pressures below 0.7 bar or at low rates of
discharge). In this case, press the diverter knob of the diverter
assembly (E) and turn it clockwise.
The diverter leave in this oposition until turning anti-clockwise.
Care
Dear Customer,
We want to ensure that you get long-lasting satisfaction and
pleasure from your GROHE fitting. Therefore, please read the
following care instructions because damage to the surface and
underlying material resulting from improper treatment is not
covered by warranty.
Do not use any abrasive sponges or scouring agents for
cleaning. We also advise you not to use cleaning agents
containing solvent or acid, limescale removers, household
vinegar and cleaning agents with acetic acid in them. They are
aggressive to the surface - and will leave your fitting dull and
scratched. As the formulations of commercially available
cleaning agents frequently change, we cannot guarantee they
will provide the gentle care our fitting deserves.
Clean the fitting with a little soap and a moist cloth only, then
simply rinse off and wipe dry. You can avoid lime spots by
drying the fitting each time it is used. If lime deposits do occur,
remove them with GrohClean, our environment-friendly
cleaning liquid. GrohClean is specially formulated to clean the
surface of our fittings gently. GrohClean is available from your
supplier.