Herunterladen Diese Seite drucken

IMG STAGELINE PAK-312M/SW Bedienungsanleitung Seite 2

Pa-lautsprecherbox mit 370-w-endstufe

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PAK-312M/SW
Order number 25.7170
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
PA Speaker System
with 370 W Amplifier
These operating instructions are intended for
users with basic knowledge in audio tech-
nology. Please read the instructions carefully
prior to operation and keep them for later
reference.
1 Applications
The speaker system PAK-312M/SW is suited for
numerous PA applications and can be used in
fixed installations and for mobile applications. It
is possible to use the speaker system as a floor
monitor or to place it on a speaker stand using
the stand sleeve.
The speaker system is designed as a 12/2 full-
range bass reflex system and is equipped with a
30 cm bass speaker (12") and a coaxial 25 mm
horn tweeter (1"). A digital amplifier (class D,
300 W) is used for bass frequencies, and an
analog amplifier (class A /B, 70 W) is used for high
frequencies. The audio signals pass a digital signal
processor (DSP) including a signal limiter.
2 Safety Notes
The unit corresponds to all relevant directives of
the EU and is therefore marked with
WARNING The unit uses dangerous mains volt-
age. Leave servicing to skilled per-
sonnel only! Inexpert handling may
result in electric shock.
The unit is suitable for indoor use only. Protect
it against dripping water and splash water, high
air humidity and heat (admissible ambient tem-
perature range: 0 – 40 °C).
Do not place any vessel with liquid on the unit,
e. g. a drinking glass.
Immediately disconnect the mains plug from the
socket
1. if the unit or the mains cable is visibly
damaged,
2. if a defect might have occurred after the unit
was dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled
personnel.
Never pull the mains cable to disconnect the
mains plug from the socket, always seize the
plug.
For cleaning only use a dry, soft cloth; never use
water or chemicals.
No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is
not correctly connected or operated, or if it is
not repaired in an expert way.
If the unit is to be put out of operation
definitively, take it to a local recycling
plant for a disposal which is not harmful
to the environment.
ELECTRONICS FOR SPECIALISTS
PAK-312M/SW
3 Connections and Control Elements
Prior to connecting or changing connections,
.
always switch off the speaker system and the
units to be connected!
1 Input signal switch to switch between micro-
phone level and line level for input A
2 Switch for sound adjustment
MUSIC
= music reproduction
FLAT
= no sound modification
LOWCUT = filter for suppressing low frequen-
cies (≤ 120 Hz) activated
3 LED indicators
ON = power indicator
SIG = signal indicator
CLIP = overload indicator
4 Volume control MASTER
CAUTION Never adjust a very high vol-
volumes which do not seem to be that high
any more after some time. Therefore, do not
further increase a high volume after getting
used to it.
5 POWER switch
6 Inputs (XLR /6.3 mm jack, bal.) to connect units
with line outputs (mixer, MP3/CD player, etc.)
When the input signal switch (1) has been set
to the position MIC, a microphone can be con-
nected to the upper jack A.
7 Feed-through outputs
At these outputs, the signals of the corre-
sponding input jack (6) are available so that
they can be sent to another active speaker sys-
tem, for example.
8 Output jack MIX OUT
At this jack, the mixed signal of the two input
jacks (6) is available; the level depends on the
position of the control MASTER (4).
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
1
2
LINE
MIC
MUSIC
FLAT
LOW CUT
MIC / LINE IN A
LINE OUT A
LINE IN B
LINE OUT B
6
7
ume. Permanent high volumes
may damage your hearing! Your
ear will get accustomed to high
ELECTRONICS FOR SPECIALISTS
3
4
5
ON
SIG
CLIP
MASTER
POWER
230 V~ /50 Hz /350 VA
0 dB
USE ONLY WITH A 250V FUSE
T5AL
MIX OUT
MONACOR INTERNATIONAL
ZUM FALSCH 36 · 28307 BREMEN · GERMANY
8
9 Support for the mains fuse
Always replace a blown fuse by one of the
same type.
10 Mains jack for connection to a mains socket
(230 V/50 Hz) by means of the mains cable
supplied
4 Specifications
Amplifier power
bass: . . . . . . . . . 300 W
treble: . . . . . . . . 70 W
Frequency range: . . . . . 50 – 20 000 Hz
Inputs
sensitivity: . . . . . . 500 mV (LINE),
input A can be
switched to 7 mV (MIC)
impedance: . . . . . 30 kΩ (LINE) / 1 kΩ (MIC)
connection: . . . . . combined XLR /6.3 mm
jack, balanced
Max. SPL: . . . . . . . . . . . 122 dB
High pass filter (low cut): 120 Hz, 24 dB/octave
Power supply: . . . . . . . . 230 V/50 Hz
Power consumption: . . . 510 VA max.
Ambient temperature: . 0 – 40° C
Dimensions: . . . . . . . . . 480 × 380 × 500 mm
Weight: . . . . . . . . . . . . 19 kg
Subject to technical modification.