Herunterladen Inhalt Inhalt Diese Seite drucken

Climate Rating; Saving Energy; Electrical Connection - SWISSCAVE WLI-GOF Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Place the device on a firm, dry and plain-
level surface. The cabinet should not be
exposed to temperatures below freezing
point, nor to vibrations, pushes or wet
environment.
4. Standard EN 378 specifies that the room in
which you install your appliance must have
a volume of 1 m3 per 8 g of R 600a
refrigerant used in the appliance, so as to
avoid the formation of inflammable gas/air
mixtures in the room where the appliance is
located in the event of a leak in the
refrigerant circuit. The quantity of refrigerant
used in your appliance is indicated on the
type plate on the inside of the appliance.
5. Always install the appliance directly against
the wall.
6. With the front levelling screws the cabinet
can be plain levelled so that it stands
completely straight, even if there is any
unevenness in the floor.
7. After definitive placement of the cooling
cabinet it should not be connected to power
for the duration of at least 12 hours. The
compressor may be damaged if this
instruction isn't followed.
6

Saving energy

• Always ensure good ventilation. Do not
cover ventilation openings or grille.
• Always keep fan slits clear.
• Avoid positioning the appliance in direct
sunlight or near cookers, radiators or similar
sources of heat.
• The energy consumption depends on the
installation conditions, e.g. the ambient
temperature.
• Keep the time the appliance is open to a
minimum.
7

Climate rating

The
climate
rating
temperature at which the appliance may be
operated in order to achieve full refrigeration
performance. The climate rating is indicated on
the type plate.
Climate rating
SN
N
ST
T
SN-ST
SN-T
Do not operate the appliance outside the
specified room temperature range!
8

Electrical connection

• Only operate the appliance with alternating
current (AC).
• The permissible voltage and frequency are
indicated on the type plate. The position of the
type plate is shown in the section entitled
Description of the appliance.
• The socket must be properly earthed and
protected by a fuse.
• The tripping current of the fuse must be between
10 A and 16 A.
• The socket must not be situated behind the
appliance and must be easily accessible!
• Do not connect the appliance using an extension
cable or extension socket.
Do not use stand-alone inverters (conversion of
direct current to alternating/three-phase current)
or energy-saving plugs. Risk of damage to the
electronic control system!
indicates
the
room
Room temperature
+10 °C to +32 °C
+16 °C to +32 °C
+16 °C to +38 °C
+16 °C to +43 °C
+10 °C to +38 °C
+10 °C to +43 °C
13