Note: When using the control panel for the first time, please reset the system before operation.
RESET THE SYSTEM:
To reset the system, press and hold the [ ▲ ] and [ ▼ ] keys simultaneously. The device beeps and the display shows „
starts to move down and to the lowest position. Never release the keys until the unit beeps again. The desk will move up a little and the
display will show the current desk height. The reset process is finished.
HEIGHT ADJUSTMENT:
• Press and hold the [ ▲ ] / [ ▼ ] button to raise/lower the desk to the desired height. Press and release the button to raise/lower the desk
precisely.
TIMER:
• Press the [ T ] button to set the time period after which the user is to be reminded to get up. Each press of the [ T ] button will increase the time
setting by 0.5 hours. The maximum time setting is 2 hours. After setting a time period, the display flashes for 1-2 seconds and automatically
returns to displaying the current height of the desk and the LED indicator light is constantly on.
• Once the time is up, 5 beeps will sound.
• To cancel the timer function, press the [ T ] button repeatedly until the display shows the current altitude and the LED indicator light is off.
MEMORY SETTING (MEMORY-SLOT):
• To save the current height setting to a memory slot, press the [ M ] key and the display will start flashing „
press the [ 1 ], [ 2 ] or [ 3 ] button.
• To recall a stored position, press the memory button [ 1 ], [ 2 ] or [ 3 ] and the system starts to move to the desired memory position. While
moving to the stored memory position, the display shows the current altitude. To stop the movement, press any button.
DISPLAY LOCK / OPERATION LOCK:
• For security reasons, this control panel has a lock function. To enable/disable the lock function, follow the instructions in section "Custom
programming: screen lock settings".
• To lock the operation, press [ M ] button for 3 seconds. When the operation lock is active, an indicator „
• To disable operation lock, press [ M ] button for 3 seconds. The current altitude is shown in the display. The operation lock is deactivated for 1
minute. If no button is pressed within 1 minute, the operation lock is reactivated.
SWITCH BETWEEN „CM" AND „INCH":
• To switch between „cm" and „inch" setting, press [ T ] button for at least 3 seconds.
ENERGY-SAVING MODE:
• If no button is pressed for more than 10 minutes, the system switches to energy-saving mode and the display goes dark.
• Press any button to reactivate the display/system.
These repair instructions are intended to help you identify and correct minor problems caused by unusual operation of the electrical system of our sit-stand
table.
If the following instructions do not help to solve the problems, please contact your place of purchase to get the service and replace the
accessories.
ERROR
E01 / E07
An electrical problem has occurred. Unplug the power cord and plug it back in.
HOT
The system has overheated. Stop operation and allow the desk to idle for approximately 18 minutes.
E02
The support legs move asynchronously. Reset the system.
E04
The control panel is not connected. Check the connection. Unplug the power cord and reconnect it.
OPERATING CONTROL PANEL
D-4
D-5

TROUBLESHOOTING GUIDE

D-1
: Timer / back / cancel
D-2
: Memory / Screen lock / next / save
D-3
: Downward
D-7
D-4
: Upward
D-5
: Memoryslot 1 / 2 / 3
D-6
: LCD-Display
D-6
D-7
: LED-Indicator light
DESCRIPTION
11
ENGLISH
" and the desk
". While „
" is displayed,
" lights up in the display.