Herunterladen Inhalt Inhalt Diese Seite drucken

Alarmcodes; Trouble Shooting - Valsir MUSTANG 160 V2 Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30

9. Trouble shooting

In case of malfunctioning check:
9.1 Presence of mains voltage
9.2 Integrity of cables and electrical connection wires
If the fault cannot be identified, send the equipment to the Manufacturer or to an
authorized technical assistance center.
Any repairs carried out on the machine by unauthorized personnel will cause the
warranty to be void.
ALARM CODES
material involved in the joint (fitting and pipes). Valsir S.p.A. declines all responsibility for
welding performed with material already used in processes in which alarm messages
have occurred.
The alarms are signaled by the flashing of the red LED and the simultaneous emission of
an acoustic signal (beep). Each alarm emits a precise number of flashes every 2 seconds.
The cycle repeats continuously. Press STOP to reset the error.
Summary
Flashes and
Alarm description
beeps in 2
seconds
The machine cannot reach
1
the current required to weld.
2
Interrupted circuit
The
requirements
3
welding are missing
Welding interrupted by the
4
user
5
Overheating
Ambient temperature is too
6
high
Short
circuit
7
terminals
When an alarm occurs, the welding process is interrupted (if in
progress) with the consequent possible degradation of the
Cause
The fitting load is too high
or
interrupted.
The
interrupted.
The
to
start
disconnected. The ambient
temperature
range.
The user has pressed STOP
Consecutive weldings too
close together.
Ambient temperature is too
high
of
welding
Worn
compliant fitting
the
fitting
circuit
is
fitting
circuit
is
fitting
has
been
is
out
of
terminals,
non-
Solution
Replace the fitting.
Chek the cables' integrity.
Check the power supply.
Replace the fitting.
Recheck
environmental
conditions
and
connections
Start a new welding
Protect the machine from
direct sunlight and extend
the cooling time of the
machine
Check the environmental
conditions and let the
machine to cool down
Replace the fitting.
Replace
the
welding
terminals
EN
19

Werbung

Inhaltsverzeichnis
loading