Temperature Scale 2/3
Page 52
© 2016 OJ Electronics A/S
All manuals and user guides at all-guides.com
• Minimum Temp. Limit – use this setting to maintain a comfort temperature on tile
floors. Can be set between 5°C and 25°C.
• Maximum Temp. Limit – use this setting to protect wooden floors from excessive
temperatures. Can be set between 10°C and 40°C.
NOTE: If the maximum limit for floor temperature is set too high, sensitive floor types
may be permanently damaged .
1 . Tap the "Menu" button on the home screen .
2 . Then tap the "engineer settings" button .
3 . Scroll down and tap the "Temp. scale" button .
4 . Confirm that you want to set minimum and maximum operating temperatures for
the thermostat by tapping "√" or cancel with "X" .
5 . If "√" is chosen, you can set a Minimum Temp .Scale .
6 . Use the "up arrow" or "Down arrow" button to change the Minimum Temp .
Scale .
7 . Confirm the setting with "√" .
8 . You can now set a Maximum Temp .Scale .
9 . Use the "up arrow" or "Down arrow" button to change the Maximum Temp .
Scale .
10 . Confirm the setting with "√" .
If "Room/Floor Limit" has been selected under "sensor application", proceed
to step 10 . Otherwise, proceed to step 16 .