6 Configuring with the programming assistant
Error 2: Drive was removed during the configuration pro-
rESEt
cess
E2
The USB drive was removed during configuration. The process
is aborted. The counter must be restarted to reset any possible
errors in the configuration. This is shown by the message "rE-
SEt" on the display. Press any key on the counter to restart it.
In order to reconfigure the counter, remove the USB drive and
insert again.
Error 3: A configuration command has produced an error
rESEt
message
E3 XXX
A command error has occurred during configuration of the
counter, i.e., one of the commands in the configuration file re-
ported an error. The digits shown here as XXX (e.g., 014) refer to
the command error in the configuration file. It represents the
sequential number of the executed commands, not the row
number. Example: If error "14" is displayed, the error is con-
tained in the 14th command in the configuration file, irrespec-
tive of how many comments are noted.
Configuration has been aborted
USB
This message appears in the display if the configuration pro-
Abort
cess is not started within the specified time after finding the
configuration file, or if the process is manually aborted. The
display returns to standard view after a couple of seconds.