Setup Manual - RDM Isolator

Overview

The RDM isolator repeats DMX and e:pix (one way) as well as RDM (bi-directional)
signals over a galvanic isolation barrier. The power supply has a separate isolation
barrier ("external" selected) or is aligned with the output potential ("DMX power"
selected). In some cases DMX cable electrically connect installations with different
power sources (with slightly different electrical potential) this may result in unwanted
links causing ground loops or earth loops. Also, long cable runs cause signal at-
tenuation. A signal amplification is required every 32 DMX fixtures or a cable length
of more than 300 meters for DMX, for e:pix every 200 meters.

Key Features

y Flexible data ports (RJ45 or screw terminals)
y USITT DMX-512A and e:pix compatibility
y Full ANSI E1.20-2010 RDM support
y Device can be powered by power back via TXconnectdata (RJ45 output)
y Separate, fully isolated power supply port

Delivery content

y RDM Isolator
y 2 x 3-pole screw terminal plugs
y 2-pole screw terminal plugs
y This setup manual

Inspection

Unpack the VMC and inspect all parts for completeness. Keep the packaging for
use in case of further transport. If there is apparent damage to the device or parts
are missing from the delivery scope, please contact Traxon Technologies service.