8. Storage
Your Gas Bottle must be stored outdoors in a well ventilated area and must
be disconnected from your gas grill when not being used. Ensure that you are
outdoors and away from any sources of ignition before attempting to discon-
nect your gas bottle from your gas grill. When you are using your gas grill after
a period of storage, please ensure to check for gas leaks and check for any
obstructions in the burner etc. before using. Also follow the cleaning instruc-
tions to ensure gas grill is safe.
If gas grill is stored outdoors ensure to check that all areas under the front
panel are free from any obstructions (insects etc.) This area must be kept free
as this may affect the flow of combustion or ventilation air.

9. Cleaning instructions

Maintenance is recommended that every 90 days for your gas grill, but it is
absolutely necessary to perform maintenance at least once a year. By doing
so, you will extend the life of your gas grill. Your gas grill is easy to clean with
minimum effort, just follow these helpful hints for cleaning convenience.
Trouble Shooting
Emergencies
Gas leaking from cracked/cut/
burned hose
Gas leaking from LP tank
Gas leaking from LP tank
valve
Gas leaking between LP tank
and regulator connection
Fire coming through control
panel
Possible cause
Damaged hose
Mechanical failure due to
resting or mishandling
Failure or tank valve from
mishandling
or mechanical failure
Improper installation, connec-
tion not tight, failure of rubber
seal
Fire in burner tube section of
burner due to partial blockage
Prevention/ Solution
Turn off gas at LP tank, if
hoes is cut or cracked, re-
place hose.See LP tank lead
test and connection regulator
to the LP
Turn off LP tank valve
Turn off LP tank valve. Return
LP tank to gas supplier
Turn off LP tank valve, re-
move regulator from cylinder
and visually inspect rubber
seal for damage, see LP tank
test and connection regulator
to the LP tank
Turn off control knobs and LP
tank valve. After fire is out and
grill is cold, remove burner
and inspect for spider nests or
rust. see natural hazard and
cleaning the burner assembly
pages.