Replacing the impeller unit
How to proceed:
 C
1. Pull the filter housing from the pump.
2. Remove the foam filter from the filter housing and rinse it out.
3. Pull the cover off the impeller unit (bayonet closure, turn clockwise).
4. Pull out the impeller unit and clean or replace.
5. Reassemble the unit in the reverse order.
Changing the battery
How to proceed:
 E
1. Turn the remote control over and remove the cover.
2. Replace the battery.
– Use a button cell battery of the type CR 2032.
3. Close the cover.
Wear parts
 Impeller unit
 Foam filter
 Bulb
 Rechargeable batteries/batteries
Storage/overwintering
Observe the permissible operating temperature range. ( Technical data)
 If the limit values are exceeded or gone below, it is necessary to remove the unit. Clean the unit thoroughly and check
it for damage.
 Store the unit in a dry and frost-free place.
 Store the pump submerged and in a frost-free environment.
Disposal
NOTE
This unit contains electronic components - do not dispose of this unit with domestic waste!
 Render the unit unusable by cutting off the cables.
 Remove the replaceable or rechargeable batteries from the unit and dispose of them separately via the re-
turn system provided for this purpose.
 Dispose of the unit by using the return system provided for this purpose.