Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA MTF-1 Einbauanleitung Seite 16

Drucksensormodul bis 1.000 bar
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Specifications
Specifications
Ingress protection (IP code) per IEC 60529
Spanner width 19 mm
EN
Spanner width 27 mm
Pin assignment
Short-circuit resistance
Analogue signals
Digital signals
Reverse polarity protection
Insulation voltage
Material (wetted)
Process connection and sensor
Material (in contact with the environment)
Case
Potting
Cover
Vibration resistance per
IEC 60068-2-6
Shock resistance per
IEC 60068-2-27
Free fall per IEC 60068-2-31
Individual packaging
Multiple packaging
Service life
Optional temperature output
Measuring range
Max. measuring deviation
1) The overpressure limit is based on the sensor element used. Depending on the selected process connection
and sealing, restrictions in overpressure limit can result. With increased overpressure limit there are
deviations in temperature error and long-term stability.
16
IP-3x
IP-1x
→ See below
S+ vs. U-
U+ and U- vs. SDA, SCL, RES
U+ vs. U- (only for analogue signals)
DC 500 V
Stainless steel 316L, PH grade steel
Stainless steel 316L
Silopren
®
PBT GF30
20 g, 10 ... 2,000 Hz
600 g, 1 ms
1 m [3.3 ft]
0.5 m [1.6 ft]
100 million load cycles
10 million load cycles for measuring ranges
> 600 bar/7,500 psi
-20 ... +100 °C [-4 ... +212 °F]
Measuring range -20 ... +60 °C
[-4 ... +140 °F]
Measuring range 60 ... 80 °C
[140 ... 176 °F]
Measuring range 80 ... 100 °C
[176 ... 212 °F]
WIKA installation instructions, model MTF-1
±3.5 K
±4.75 K
±6 K

Werbung