8.
When will the Alarm be activated
-
If the CO level (PPM) in the room is too high, the carbon monoxide detector switches to the
alarm mode according to the scheme below:
030 - 049 PPM : Alarm signal after 120 minutes
050 - 099 PPM : Alarm signal after 60 - 90 minutes
100 - 299 PPM : Alarm signal after 10 - 40 minutes
>300 PPM : Alarm signal within 3 minutes
9.
Health effects of carbon monoxide
100 - 200 PPM : Mild headache, nausea, vomiting, fatigue (often described as 'flu-like'
200 - 400 PPM : Severe headache, confusion, dizziness, accelerated heart rate.
>400 PPM : Unconsciousness, coma, heart/lung failure, death.

10. Maintenance

-
We recommend to manually test the detector once a month by pressing and holding the test
button. If problems are found, the detector switches to the error mode (either siren error or
sensor error). We recommend to manually test the detector at least once a year by pressing
and holding the test button.
-
Dust is a major cause of false alarms. Therefore, clean the carbon monoxide detector once a
month. Use a vacuum cleaner to gently remove any accumulated dust along the sides of the
carbon monoxide detector. Never use a wet cloth or detergent to clean your alarm, as this
can be harmful to the sensor.
11. Warnings
This manual contains important safety information about the installation and operation of
the alarm. Read the manual carefully and keep it in a safe place for future reference.
-
This device must be installed by a qualified person
-
The installation of a carbon monoxide detector should not be a substitute for proper
installation, use and maintenance of combustion appliances and suitable ventilation and
exhaust systems.
-
This product is not water resistant and is only suitable for indoor use. Only clean the product
with a dry cloth.
-
Do not try to repair the device, it has the risk of electric shock or malfunction if the device is
tampered with.
-
Do not expose the product and batteries to extreme temperatures.
-
The following substances can affect the sensor and cause false alarms:
methane, propane, isobutylene, isopropanol, ethylene, benzene, toluene, ethyl acetate,
hydrogen sulfide, sulfur dioxide, alcohol-based products, paints, thinners, solvents,
adhesives, hair sprays, aftershaves, perfumes and some cleaning agents.
symptoms).