OPERATION

Switch ON the unit and start heater by adjusting the function switch (No.2
Fig.2) to the position reqired:
heating 9kW or
heating 18kW or
fan mode
(A, B or C Fig.5.) The space heater is equipped with an adjustable thermostat.
The temperature required is set by means of the adjustment button (No.1
Fig.2). after which the heater runs automatically.
The machine must be cooled down before switching it off by turning func-
tion switch to the position shown in pos. C. Fig.5 (
fan mode). With such a
settings machine have to work for 10 minutes time before switching over to
OFF (pos. D Fig.5) or before interrupting the mains supply.
IMPORTANT! Cooling down
The heating elements get very hot, so it is important that they cool down after
use before switching off in order to maximise the machine's lifespan and to
prevent damaging of the textile Multidirectional Air Distribution Unit.
To get this turn the function switch to the position shown in pos. C. Fig.5
(
fan mode).
Let machine works c.a. 10 minutes to cool down properly. This must be done
every time the machine is turned off, prior to filter replacement or before the
machine is moved.
POST VENTILATING
To prevent problems caused by switching off without prior cooling down, post
ventilating function has been implemented. Function is automatically used in
case of improper switching off the device without prior cooling down or too
short cooling time. After turning OFF the machine using the function switch to
position
(pos.D Fig.5) ventilator will work. This could be executed with time
delay (several seconds without any action) or without (will continue working).
After machine cooling down ventilator will be switched off.
Filter replacement
NOTE! Use a protective mask, safety glasses and gloves when replacing the air
filter. Put the spent filter in a bag and close it.
Replace the filter once a month or as necessary. The filter must be fitted so
that the arrow on the filter points inwards towards the machine. Always use
original filters from Inelco.
• Cool down the heater for 10 minutes and turn OFF the machine using the
function switch (pos.D Fig.5) .
• Replace the filter
• Turn ON the machine turning the function switch to required position (pos. A,
B or C Fig.5) .