Hydro Unit
Anti bacteria
This function performs anti-bacteria operation of the
hot water tank.
• When the ANTI BACTERIA
pressed, the
mark appears on the remote
controller and the anti-bacteria operation is
reserved.
• The anti-bacteria operation is performed to maintain
the preset temperature (75°C) for the set time period
(30 minutes) when the preset start time (22:00)
comes according to the preset interval (7 days).
• The settings of these interval, start time, and
temperature maintaining time period can be
changed, but ask the installation company for the
setting change.

Schedule timer

button is
Operations can be scheduled in eight STEPs for each
day of the week.
(Example)
• Monday
STEP1
STEP2
STEP3
STEP4
STEP5
• Tuesday to Saturday: Same as Monday
• Sunday
STEP1
Setting the schedule function
Press the SCHEDULE
SET
is blinking. The
schedule function starts working.
Cancelling the schedule function
Press the SCHEDULE
CL
blinking. The
function is cancelled.
Setting schedule
Press the SCHEDULE
more to enter the schedule setting mode.
Perform the following procedure to set the
schedule
• First schedule setting
Procedure:
– 10 –
(Disable with second remote control)
04:00 ZONE1
Heating 45°C, hot water 50°C
07:00 ZONE1
Heating 50°C, hot water 45°C
Heating disabled, hot water
10:00 ZONE1
45°C
16:00 ZONE1
Heating 50°C, hot water 50°C
23:00 ZONE1
Heating 40°C, hot water 45°C
04:00 ZONE1
Heating 45°C, hot water 50°C
button and press the
button within five seconds while the
mark changes to lighting and the
button and press the
button within five seconds while the
mark disappears and the schedule
button for 4 seconds or
1
2
3
4
Owner's Manual
mark
mark is
5
6
EN
10-EN

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis