required for long hallways, and this also applies to hallways
with a width of < 1 m.
Mounting fixtures and tips for rooms
with sloped / high ceilings
The rules for sloped ceilings with an incline of less than 20 °
are the same as those for horizontal ceilings (see picture G).
Please install the smoke alarm as indicated in igure B for
rooms with a ceiling incline of > 20 °.
The maximum installation height of the smoke alarms
should not exceed 3 m. The smoke alarms are installed at
multiple levels, if the installation height is more than 3 m.
In the case of rooms with sloping roofs and horizontal ceilings:
Expect to install it on the sloped ceiling, if the horizontal
section of the ceiling is smaller than 1 m. The alarm should
be installed in the middle of the horizontal ceiling, if the
horizontal section of the ceiling is more than 1 m.

Installing smoke alarms

Turn the housing to the left, to open and remove it from the
mounting bracket.
Keep the mounting plate
in the position that you want
4
to install the smoke alarm. Mark the holes with a pencil.
These markings are necessary for the mounting holes.