Herunterladen Diese Seite drucken

Zander Aachen SCB Serie Kurzanleitung Seite 5

Sichere zeitsteuerung
Vorschau ausblenden Andere Handbücher für SCB Serie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

S a f e t y T i m e C o n t r o l D e vi c e S CB
Brief instructions for electricians
Errors and technical modifications excepted
Block diagram
The Block diagram shows variant SCB-04. Other variants differ in output
configuration.
SCB-04: Two safe HL outputs - O1, O2 and two safe relay contacts - 17-18, 27-28.
SCB-03: Three safe HL outputs - O1, O2, O3
SCB-02: Two safe relay contacts - 17-18, 27-28
Terminal function
Terminal
A1
A2
I11
I21
I12
I22
X1
Y1
17-18 / 27-28
O1, O2, O3
C1
C2
Application example 1:
SCB-04 for time-delayed switch-off of a drive with safe immediate signal to safe control
for controlled stop with automatic reset
Application example 2:
SCB-02 for filtering limit value transgressions with automatic re-trigger function
Function
Power supply - DC 24V
Power supply - 0V
Safe input channel 1 1
Control voltage channel 1
Safe input channel 2
Control voltage channel 2
Start input
Input for feedback loop
Safe relay contacts (depends on variant)
Safe semiconductor outputs
(depends on variant)
Auxiliary output 1
Auxiliary output 2
Configuration table of all SCB-04 variants
Non-delayed
Configuration No.
outputs/contacts
Man. reset
Auto
Man.
17/
with autom.
O1 O2
Start
Start
18
re-triggering
00
11
01
12
02
13
03
14
04
15
05
16
06
17
22
07
18
23
08
19
24
09
20
25
10
21
26
27
For variant SCB-04
27
For variant SCB-04m /
SCB-04h
28
29
F1: AUX C1 switches as an immediate signal to delayed safe outputs/contacts.
F2: AUX C2 switches as an error signal
F3: AUX C1 switches inverted to non-delayed outputs/contacts.
F4: AUX C2 switches inverted to delayed outputs/contacts
F5: AUX C1 switches inverted to safe relay contacts 17-18/27-28
F6: AUX C2 switches in parallel to safe relay contacts 17-18/27-28
n.F.: Corresponding message output has no function
Configuration table of all SCB-03 variants
Non-delayed
Configuration No.
outputs/contacts
Man. reset
Auto
Man.
with autom.
O1
O2
Start
Start
re-triggering
00
07
01
08
02
09
03
10
04
11
14
05
12
15
06
13
16
17
18
F1: AUX C1 switches as an immediate signal to delayed safe outputs.
F2: AUX C2 switches as error signal
F3: AUX C1 switches inverted to non-delayed outputs
F4: AUX C2 switches inverted to delayed outputs.
F5: AUX C1 switches inverted to O3
F6: AUX C2 switches parallel to O3
n.F.: Corresponding message output has no function
Configuration table of all SCB-02 variants
Non-delayed
Configuration No.
contacts
Man. Start
Auto
Man.
mit autom.
17/18
27/28
Start
Start
Re-
Triggerung
00
03
01
04
02
05
06
F1: AUX C1 switches as an immediate signal to delayed safe contacts.
F2: AUX C2 switches as an error signal
F5: AUX C1 switches in parallel to safe contacts
F6: AUX C2 switches inverted to safe contacts
AUX Functions
Delayed
SCB-
SCB-
outputs/contacts
04x
04x-01
27/
17/
27/
O1 O2
C1 C2 C1 C2
28
18
28
F1 F2 F3 n.F.
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 n.F. F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 n.F. F4
F5 F6 F5 F6
F1 F2 F3 n.F.
F5 F2 F5 F6
F5 F2 F5 F6
AUX Functions
Delayed
SCB-
SCB-
outputs/contacts
03x
03x-01
O3
O1
O2
O3
C1 C2 C1 C2
F1 F2 F3 n.F.
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 n.F. F4
F1 F2 F3 F4
F1 F2 F3 F4
F1 F2 n.F. F4
F6 F2 F5 F6
F6 F2 F5 F6
AUX Function
Delayed contacts
SCB-
SCB-
02x
02x-01
17/18
27/28
C1 C2 C1 C2
F1 F2 F5 F6
F1 F2 F5 F6
F1 F2 F5 F6 OFF-Delay
Function
None
On-Delay
Off-Delay
Time delay-
ed reset
None
Wiping
Wiping
Function
None
ON-Delay
OFF-Delay
Wiping
Wiping
Function
None
ON-Delay
N09
E61-471-00
Ver. B
5

Werbung

loading

Diese Anleitung auch für:

Scb-04Scb-03Scb-02