EDL- 6
Order No. 1000263
ELECTRONICS FOR SPECIALISTS
PA Ceiling Speaker
These instructions are intended for installers
with sufficient knowledge of 100 V technol-
ogy for PA applications. Please read the in-
structions carefully prior to installation and
keep them for later reference.
1 Applications
This speaker is specially designed for applications
in PA systems. It is equipped with a transformer for
operation in 100 V systems.
2 Safety Notes
The speaker corresponds to all relevant directives
of the EU and is therefore marked with
The speaker is suitable for indoor use only. Pro-
tect it against dripping water, splash water and
high air humidity. The admissible ambient tem-
perature range is 0 – 40 °C.
For cleaning only use a dry, soft cloth; never use
water or chemicals.
No guarantee claims for the speaker and no lia-
bility for any resulting personal damage or ma-
terial damage will be accepted if the speaker is
used for other purposes than originally intended,
if it is not correctly installed or connected, or if
it is overloaded.
If the speaker is to be put out of opera-
tion definitively, dispose of the speaker in
accordance with local regulations.
3 Mounting
1) Saw a hole of the corresponding size into the
ceiling (⌀ 170 mm).
2) Make the electrical connection (chapter 4).
3) Fold the two clamps upwards.
4) Insert the speaker into the ceiling cutout until
the clamps are folded down and the speaker is
clamped on the ceiling.
ELECTRONICS FOR SPECIALISTS
.
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
ELECTRONICS FOR SPECIALISTS
4 Electrical Connection
WARNING During operation, there is a hazard
Observe the load of the speakers on the PA am-
plifier. Overload may damage the amplifier! The
total power of all speakers connected must not
exceed the amplifier power.
1) If the PA system is switched on, switch it off
completely before connecting it!
2) Connect the speaker via the screw terminals
(black core = negative pole).
3) When connecting several speakers, make sure
that all speakers have the same polarity and
that the PA amplifier is not overloaded.
5 Specifications
Power rating: . . . . . . . . 8 W
Frequency range: . . . . . 90 – 18 000 Hz
Sensitivity: . . . . . . . . . . . 90 dB (1 W/1 m)
Max. rated SPL: . . . . . . . 99 dB
Radiation angle: . . . . . . 90°
Voice coil: . . . . . . . . . . . ⌀ 20 mm
Ambient temperature: . 0 – 40 °C
Outside diameter: . . . . . 193 mm
Mounting cutout: . . . . . ⌀ 170 mm
Mounting depth: . . . . . 65 mm
Total depth: . . . . . . . . . 72 mm
Weight: . . . . . . . . . . . . 492 g
ELECTRONICS FOR SPECIALISTS
of contact with a dangerous voltage
of up to 100 V at the speaker cable.
Installation must always be carried
out by skilled personnel.
Subject to technical modification.
A-2098.99.01.04.2021