Disconnecting the Sensor
From the Patient Cable:
LNCS
1. Refer to Fig. 6a. Lift the protective cover to gain access to the sensor connector.
2. Refer to Fig. 6b. Pull firmly on the sensor connector to remove from the patient cable. To avoid damage, pull on the
sensor connector, not the cable.
M-LNCS
1. Refer to Fig 7. Pull firmly on the sensor connector to remove it from the patient cable. To avoid damage, pull on the
sensor connector, not the cable.
From the Patient:
1. Pull gently on the anchor pad and remove from the patient's shoulder.
2. To remove the E1 Ear Sensor from the patient's ear, gently pull apart the emitter and detector and remove.
CAUTION:
To avoid discomfort to the patient or damage to the sensor, do not remove the sensor from the patient's ear by pulling on the cable.
CAUTION:
Avoid positioning the patient so that external pressure is applied to the sensor at the measuring site.
CAUTION:
To prevent damage, do not soak or immerse the sensor in any liquid solution. Do not sterilize by irradiation, steam, autoclave or
ethylene oxide.

SPECIFICATIONS

When used with Masimo SET pulse oximetry monitors, Masimo rainbow SET pulse CO-Oximetry monitors, or with licensed
Masimo SET pulse oximetry or Masimo rainbow SET pulse CO-Oximetry modules, and patient cables, during no motion, the
saturation accuracy of the E1 Ear Sensor from 70-100% is ± 2.5% (1 Std. Dev.). Pulse rate accuracy (from 25-240 bpm), during
no motion is ± 3 bpm (1 Std. Dev.) and low perfusion accuracy is ± 3 bpm (1 Std. Dev.).
SpO2 accuracy was determined by testing on healthy adult volunteers in the range of 70% -100% SpO2 against a laboratory
co-oximeter. Accuracy specifications are statistically distributed, and only about two-thirds of the measurements fall within
the 1 Std. Dev. specification.
INSTRUMENT COMPATIBILITY
Instruments and sensors containing Masimo rainbow SET technology are identified with the Masimo rainbow SET logo.
Instruments and sensors using Masimo SET technology are identified with the Masimo SET logo. These sensors are for use only
with instruments containing Masimo SET MS-2000 (Version 4.8 or higher) technology or Masimo rainbow SET MX technology.
Each sensor is designed to operate correctly only on the pulse oximetry system from the original instrument manufacturer.
Use of this sensor with other instruments may result in no or improper performance. Look for the Masimo SET or Masimo rainbow
SET designation on both the sensors and monitors to ensure accurate pulse oximetry when needed most.
For Compatibility Information Reference: www.Masimo.com
WARRANTY
Masimo warrants to the initial buyer only that this product, when used in accordance with the directions provided with the
Products by Masimo, will be free of defects in materials and workmanship for a period of six (6) months. Single use products
are warranted for single patient use only.
THE FOREGOING IS THE SOLE AND EXCLUSIVE WARRANTY APPLICABLE TO THE PRODUCTS SOLD BY MASIMO TO BUYER.
MASIMO EXPRESSLY DISCLAIMS ALL OTHER ORAL, EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION
ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. MASIMO'S SOLE OBLIGATION AND BUYER'S
EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY SHALL BE, AT MASIMO'S OPTION, TO REPAIR OR REPLACE THE PRODUCT.

WARRANTY EXCLUSIONS

This warranty does not extend to any product that has been used in violation of the operating instructions supplied with the
product, or has been subject to misuse, neglect, accident or externally created damage. This warranty does not extend to any
product that has been connected to any unintended instrument or system, has been modified, or has been disassembled
or reassembled. This warranty does not extend to sensors or patient cables that have been reprocessed, reconditioned or
recycled.
IN NO EVENT SHALL MASIMO BE LIABLE TO BUYER OR ANY OTHER PERSON FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR
CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), EVEN IF ADVISED OF THE POSSIBILITY
THEREOF. IN NO EVENT SHALL MASIMO'S LIABILITY ARISING FROM ANY PRODUCTS SOLD TO BUYER (UNDER A CONTRACT,
WARRANTY, TORT OR OTHER CLAIM) EXCEED THE AMOUNT PAID BY BUYER FOR THE LOT OF PRODUCT(S) INVOLVED IN
SUCH CLAIM. In no event shall Masimo be liable for any damages associated with a product that has been reprocessed,
reconditioned or recycled. THE LIMITATIONS IN THIS SECTION SHALL NOT BE DEEMED TO PRECLUDE ANY LIABILITY THAT,
UNDER APPLICABLE PRODUCTS LIABILITY LAW, CANNOT LEGALLY BE PRECLUDED BY CONTRACT.
NO IMPLIED LICENSE
THIS SINGLE-PATIENT SENSOR IS LICENSED TO YOU UNDER THE PATENTS OWNED BY MASIMO FOR SINGLE-PATIENT USE ONLY.
BY ACCEPTANCE OR USE OF THIS PRODUCT, YOU ACKNOWLEDGE AND AGREE THAT NO LICENSE IS GRANTED FOR USE OF THIS
PRODUCT WITH MORE THAN A SINGLE PATIENT.
AFTER SINGLE-PATIENT USE, DISCARD SENSOR.
PURCHASE OR POSSESSION OF THIS SENSOR CONFERS NO EXPRESS OR IMPLIED LICENSE TO USE THE SENSOR WITH ANY
DEVICE WHICH IS NOT SEPARATELY AUTHORIZED TO USE E1 Ear SENSORS.